Installation Instructions

6
PLAN THE INSTALLATION:
Recommended mounting height is 18” to 24” from the bottom of
the range hood to the top of the cooking surface.
The hood should be mounted to the bottom of a standard wall
cabinet. If the hood must be mounted directly to a wall, secure the
hood to wall studs.
All wiring must comply with local codes and the unit must be
properlygrounded.Thehoodisconnectedtoa110-120VAC
lightingcircuit(15Amp)inthecircuitbreakerorfusebox.
The model ESN130 isnon-ducted
The model EFS130 is ducted
The models ERS230, ENM230 and ENM236areconvertible(they
maybeinstalledasaductedorasanon-ductedunit).
Before installing the hood
IF THE RANGE HOOD IS TO BE NON - DUCTED:
PurchaseAccesoriesRecirculation(nonducted)kit
ERS230: ERSRCK30
ENM230 / ENM236: ENMRCK36
IF THE RANGE HOOD IS TO BE DUCTED:
Ductwork can be installed vertically or horizontally.
Duct runs should be as short as possible.
Avoid the use of elbows.
Use duct tape at all joints.
Do not use duct smaller than the discharge on the hood.
For7”roundductworkinstallation,purchaseaccessory
transition Kit:
7”(17.8cm)roundventmountingplate.
Accesories Part No.EXXTRK07(purchasedseparately).
7”(17.8cm)rounddamperNonreturnvalve.
Accesorie Part No. EXXNRVRD (purchasedseparately).
For3¹⁄
4”x10”(8.3x25.4cm)rectangularductwork
installation:
3¹⁄4” x 10” (8.3 x 25.4 cm) rectangular vent conector is
supplied.
Ifneededpurchase3¹⁄
4”x10”(8.3x25.4cm)
rectangular damper non return valve. Accessories
Part No. EXXNRVRT
7” (17.8 cm) Round Vent System
Vent Piece Round
45°elbow 2.5ft
(0.8m)
90°elbow 5.0ft
(1.5m)
7”(17.8cm) 0.0ft
(0.0m)
Wall cap
3 " x 10"
(8.3 x 25.4 cm)
elbow
2 ft
(0.6 m)
6 ft (1.8 m)
Example Vent System
Maximum Recommended Length = 50 ft (15.2 m)
1-90°elbow =5.0ft(1.5m)
8ft(2.4m)straight =8.0ft(0.0m)
1-wallcap =0.0ft(2.4m)
Lengthof3¹⁄
4” x 10”
=13.0ft(3.9m)
(8.3cmx25.4cm)system