Installation Sheet

8
Electrical Connection
I WARNING
ELECTRICAL SHOCK HAZARD.
I WARNING
DISCONNECT POWER BEFORE SERVICING.
REPLACE ALL PARTS AND PANELS BEFORE OPERATING.
FAILURE TO DO SO CAN RESULT IN DEATH OR
ELECTRICAL SHOCK.
1 Disconnect power.
2 Remove terminal box cover.
3 Remove the knockout in the terminal box cover and install
a UL listed or CSA approved
1
2” strain relief.
B
A. Knockout
B. Junction box cover
A
4 Run home power supply cable through strain relief, into
terminal box.
A B
C
D
E F
A. Home power supply cable
B. UL listed or CSA approved
strain relief
C. Black wires
D. UL listed wire connectors
E. White wires
F. Green (or bare) and
yellow-green ground wires
5 Use UL listed wire connectors and connect black wires
(C) together.
6 Use UL listed wire connectors and connect white wires (E)
together.
I WARNING
ELECTRICAL SHOCK HAZARD.
I WARNING
ELECTRICALLY GROUND BLOWER.
CONNECT GROUND WIRE TO GREEN AND YELLOW
GROUND WIRE IN TERMINAL BOX. FAILURE TO DO SO CAN
RESULT IN DEATH OR ELECTRICAL SHOCK.
7 Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (F) in terminal box
using UL listed wire connectors.
8 Tighten strain relief screw.
9 Install terminal box cover.
10 Check that all light bulbs are secure in their sockets.
11 Reconnect power.
Install duct covers
When using both upper and lower vent covers, push lower
cover down onto hood and lift upper cover to ceiling and
install with two mounting screws.
NOTE: For vented installations, the upper vent cover may be
reversed to hide slots.
D
C
C
A
B
A. Upper vent cover
B. Lower vent cover
C. 4 x 8 mm screws
D. Bracket
Secure the bottom of the duct with 2 - 4 x 8 mm screws.