Installation instructions
9
Electrical connection
WARNING
Electrical Shock Hazard
Warning: Turn off power circuit at the service panel
before wiring this unit.
120 VAC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THISAPPLIANCEISFITTEDWITHANELECTRICAL
JUNCTIONBOXWITH3WIRES,ONEOFWHICH
(GREEN/YELLOW)SERVESTOGROUNDTHE
APPLIANCE.TOPROTECTYOUAGAINST
ELECTRICSHOCK,THEGREENANDYELLOWWIRE
MUSTBECONNECTEDTOTHEGROUNDINGWIRE
INYOURHOMEELECTRICALSYSTEM,ANDIT
MUSTUNDERNOCIRCUNSTANCESBECUTOR
REMOVED.
Failure to do so can result in death or electrical
shock.
Disconnect power.
Remove terminal box cover.
RemovetheknockoutintheterminalboxandinstallaUL
listedorCSAapproved½”strainrelief.
Runhomepowersupplywiringthrough½”strainrelief
into terminal box.
UseULlistedwireconnectorsandconnectwhitewires
(B)together.
UseULlistedwireconnectorsandconnectblackwires
(C)together.
1.
2.
3.
4.
5.
6.
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
Connectgreen(orbare)groundwirefromhomepower
supplytothe2yellow-greengroundwires(D)interminal
boxusingULlistedwireconnectors.
Tightenstrainreliefscrew.
Install terminal box cover.
Reconnect power.
Mounting the duct cover
Position the duct cover over the mounted hood.
Slide the bottom of the duct into the glass area.
Position the top of the duct over the duct mounting
bracket. If a telescopic duct cover is used, grab the
upper part of the telescopic duct cover, pull it and place it
in the duct cover mounting bracket.
Secure the top of the duct with 2 assembly screws
provided.
7.
8.
9.
10.
•
•
•
•
A
B
C
D
E
A.ULlistedwireconnectors
B.White wires
C. Black wires
D.Green(orbare)wireconnectedto
yellow-green wires
E.Homepowersupply