elinca sa switzerland www.elinchrom.com Operating Manual Digital 1200 RX Digital 2400 RX Version 230 V - 10256 Version 110V - 10255 Elinca S.A Digital RX 01.06.
Table of contents Introduction 2 Declaration of conformity, disposal and recycling, CE marking 3 Before you start, Safety notice 4 Control Panel 5 Operating instructions 6 Functions 6, 7 Relation of power between the outlets 8 Fuse 8 Flasheads 9 Symmertical/Asymmetrical power distribution 10 Flashheads compatibility 10 Flashhead types 11 Wireless remote control and flash triggering 12 Troubleshooting 12 Elinchrom Accessories 13 Guarantee 14 P.
Introduction The Elinchrom Digital RX is manufactured by Elinca S.A. CH -1020 Renens/Switzerland Dear Photographer, Thank you for buying your Digital RX flash generator. All Elinchrom products are manufactured using the most advanced technology. Carefully selected components are used to ensure the highest quality and the equipment is submitted to many controls both during and after manufacture. We trust that it will give you many years of reliable service.
Declaration of conformity This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. Product name: Professional Studio Flash Generator Trade name: ELINCHROM Model number(s): Digital RX Name of responsible party: Elinca S.A Av.
Before you start ! User Safety Information • Keep flash units out of reach whenever possible. • Switch off when not in use and disconnect flashheads. • Do not use in restricted areas (like hospitals, etc.) • Do not use near flammable/explosive material. • It must be protected from dripping water and from extremely dusty conditions • The unit must ALWAYS be plugged into an EARTHED electrical socket.
Control Panel 4 16 17 18 19 20 1 21 2 15 3 10 7 9 11 6 5 8 12 13 14 Overview of Controls 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Mains inlet socket Fuse AC supply (16 AT, slow blow) Illuminated mains switch Modelling control (on/off free or prop) Open flash and charge indicator Slave cell on/off Handle Photocell receptor Acoustic recharging signal (Beep) Synchro-sockets, Amphenol + jack 3.5 mm Charge speed (slow charge 230 V = 10 A) 12. Decrease power adjustment in 1/10 f-stops, with ADF 13.
Operating Instructions Before connecting the digital RX for the first time, make sure that your mains supply and the rating set on the equipment (electrical specification plate) are compatible to 110V or 230V. • • • • • • • • Connect lampheads ensuring that lamphead touches (18-19) are Off. Connect the mains cord in the inlet socket (1) Select charging rate (11) (" " slow position), only when the mains supply is too limited.
Slow Charge (11) The green LED indicates that the slow charge function is selected. This position is recommended if the mains line capacity is limited for the standard fastcharge mode. Open Flash (5) When the green LED is illuminated the flash may be released manually. The release is blocked during charging, but not when the unit discharges. The integrated discharge system is protected by a thermic cut out.
Relation of power range between the outlets Guide aperture is based on the " Digital S or Digital SE " lamphead and the 50° reflector, distance 1 m/3.3 ft and film ISO 100/21 DIN. Digital 1200 RX Digital 2400 RX Scale Ws f-stop Scale Ws f-stop Power 7.5 1200 (128) 8.5 2400 (180) 1/1 6.5 600 (90) 7.5 1200 (128) 1/2 5.5 300 (64) 6.5 600 (90) 1/4 4.5 150 (45) 5.5 300 (64) 1/8 3.5 75 (32) 4.5 150 (45) 1/16 2.5 37.5 (22) 3.
Flashheads When plugging in a lamphead connector, first push in the front part, then firmly press in the whole plug, the rear part being secured by the locking spring. 2 ! 1 Do NOT plug in or unplug lampcords while the green leds on output A and B are ON (illuminated) Socket Halogen modelling lamp Use only the recommended modelling lamp, the Digital S and Digital SE heads are fitted with a 300 W halogen modelling lamp. For 230 V code 23022. Protective Pyrex Dome For use with standard halogen lamp GX 6.
Symmetrical power distribution The Digital RX power packs deliver symmetrical power distribution when the same type of flashhead is used for both power pack outlets. For example 2x Digital S or 2x A 3000 N head. Asymmetrical power distribution It is possible to set asymmetrical power distribution by using two different heads like 1x Digital S and 1x A3000N head. Instead of a 50% - 50% split, this head combination splits into 75% for the A-head and 25% for the S-head.
Flashhead Types • Digital S => Ultimate stability for digital and multishot imaging. The heavy duty electrodes resist heat stress. • Digital SE => Suitable for universal use and standard multishot imaging. The flash tube can be used up to 3000 ws • Digital SEE => This head covers all universal studio us and comes with a long life Swiss Made flash tube up to 2400 ws. • A 3000 N Speed => Unique super short flash duration with a single, twin electrode flash tube to ensure even light distribution.
Wireless Remote Control and Flash Triggering The charge socket is as well the interface for the EL-Skyport Trigger and Remote System. With the EL-Skyport RX Trigger Set 19362, the Digital RX can be triggered wireless, up to approximatly 100 m distance. Apart from triggering, the Transmitter offers modelling lamp on/off settings and flash power control in 1/10th steps.
Elinchrom Accessories code Reflectors Wide angle ø 16 cm /90° 26143 Compact ø 18 cm /60° 26144 Standard ø 21 cm /50° 26141 Mini soft ø 44 cm silver 26166 Mini soft ø 44 cm white 26168 Snoot & Grid 26061 Grid for snoot 26427 Grids Grid set for reflector 18 cm 26135 Grid set for 21 cm 26051 Filters Set of 10 color/mixed filters for 21 cm x 21 cm 26243 Polarizing filter 21 cm 26244 Square 70 x70 cm 26178 Square 100 x100 cm 26179 Lightbanks ROTALUX Umbrellas Strip 95 x 35 cm 26
GUARANTEE This ELINCHROM product will be repaired free of charge by the vending agent if during a period of 24 months from date of purchase its working order is impaired through a manufacturing or material defect. The faulty product should be immediately sent to the authorized dealer or ELINCA agent. This guarantee is not valid for equipment which has been misused, dismantled, modified or repaired by persons not belonging to the ELINCA distribution network.
www.elinchrom.