Specifications

31
If the DC2000 is automatically opening the gate due to a power failure, any manual command such as
“One-Button”, “Three Push Button”, “Key Switch”, “Photo Beam” or “Edge Sensor” will cancel the automatic
mode of the DC2000. After such cancellation, the DC2000 will continue to operate in manual mode until 110 Vac
power is restored.
Important: All devices wired to the DC2000 MUST be dedicated to it alone. Normal operation will be
controlled by separate devices wired to the OmniControl™ board.
WIRING OPTIONAL DC2000 DEVICES
Manual One-Button
Push and
“Hold”
to Open
Push again and
“Hold”
to Close
1
3
2
76
5
4
Part #
AEXITP
1
3
2
76
5
4
1
3
2
76
5
4
1
3
2
76
5
4
Key Switch
Turn and
“Hold”
to Open
Turn again and
“Hold”
to Close
Part #
A1KX
Part #
412HM
Push and
“Hold”
a Button to operate
Three-Button
1
3
2
N.O.
N.O.
N.O.
Com
Com
Com
4
4
4
Push and
“Hold”
DC2000 Transmitter Button to Open
Push again and
“Hold”
DC2000 Transmitter Button to Close
24 VDC radio receiver to
be used by OmniControl™
Board ONLY!
12 VDC Radio Receiver
Back-Up Operation Only
Normal Gate Operation
Radio Receivers
4
12 V
If 110 Vac power is on, but the
system has an electronic
malfunction, the gate can be
operated using the DC2000
system with
ANY
of these
devices shown.
EMERGENCY OVERRIDE
Jumper P3:
to 12 Volt
Jumper P2:
to Momentary (M)
6
4
5
2
3
4
1
®
Button One:
Normal Gate Operation
(OmniControl™ Board)
Button Two:
Back-Up Operation
(DC2000)
Button Three:
Optional Accessories
Wiring Optional DC2000 Devices
3 Push Button
Part #
02-103
to OmniControl™
board
DO Not Remove the
2 Factory Installed
Wires in the
J 20 Socket
Op
t
ional
Products
CSW200A Manual.qxd 12/9/04 3:11 PM Page 31