Specifications

41
SINGLE OPERATOR LOOP SIZE AND PLACEMENT
It is
VERY
important to have enough separation between loops and gates to prevent false detection.
If A =
Then C =
6 Feet
4 Feet
9 Feet
4.5 Feet
12 Feet
5 Feet
15 Feet
5 Feet
18 Feet
5.5 Feet
21 Feet
6 Feet
If B =
Then E =
6 Feet
4 Feet
9 Feet
4.5 Feet
12 Feet
5 Feet
15 Feet
5 Feet
Outside Safety Loop:
Center Loop:
This loop must have enough space between loop and gate when
opened
or
closed
.
If driveway is smaller than 18 ft, then D must be 4.5 ft
If driveway is bigger than 18 ft, then D must be 5 ft
This is for a typical single CSW200UL™ loop installation. Individual circumstances may alter dimensions.
For technical support: 1-800-528-2806
If there is no center loop, then
F 4 ft
If there is a center loop, then F = B or G which ever is largest.
Inside Safety Loop
H = G or I which ever is largest.
Exit Loop
Out
In
Center
Loop
Inside
Safety
Loop
Outside
Safety
Loop
Exit
Loop
A
BGI
CDFH
E
Distance from
open gate
Drawing not to scale
End of open gate
Caution:
Distance “E” must be a minimum of 4 feet away from open gate!
Caution:
Verify if spacing “D and C” is appropriate for the installation
and does NOT compromise safety.
Single Operator Loop Size and Placement
CSW200A Manual.qxd 12/9/04 3:11 PM Page 41