Specifications
42
MASTER/SECOND LOOP SIZE AND PLACEMENT
It is
VERY
important to have enough separation between loops and gates to prevent false detection.
If A =
Then C =
6 Feet
4 Feet
9 Feet
4.5 Feet
12 Feet
5 Feet
15 Feet
5 Feet
18 Feet
5.5 Feet
21 Feet
6 Feet
If B =
Then E =
6 Feet
4 Feet
9 Feet
4.5 Feet
12 Feet
5 Feet
15 Feet
5 Feet
Out
In
Center
Loop
Inside
Safety
Loop
Outside
Safety
Loop
Exit
Loop
A
B
F
I G
DH C
E
Distance from
open gate
E
Distance from
open gate
End of open gate
Drawing not to scale
Outside Safety Loop:
Center Loop:
This loop must have enough space between loop and gate when
opened
or
closed
.
If driveway is smaller than 18 ft, then D must be 4.5 ft
If driveway is bigger than 18 ft, then D must be 5 ft
This is for a typical master/second loop installation. Individual circumstances may alter dimensions.
For toll free technical support: 1-800-528-2806
If there is no center loop, then
F 4 ft
If there is a center loop, then F = B or G which ever is largest.
Inside Safety Loop
H = G or I which ever is largest.
Exit Loop
Caution:
Distance āEā must be a minimum of 4 feet away from open gate!
Caution:
Verify if spacing āD and Cā is appropriate for the installation
and does NOT compromise safety.
Master / Second Operator Loop Size and Placement
CSW200A Manual.qxd 12/9/04 3:11 PM Page 42