® ACCESS SYSTEMS INC eliteaccess.com Instruction Manual ROBO SLIDE Residential Gate Operator Installation instructions and manual book for architects, general contractors and dealers Click on the desired topic in the “Bookmarks” column or “Table of Contents” to select page. Copyright © 2000 by Elite Access Systems, Inc. – www.eliteaccess.
T A B L E O F C O N T E N T S 2 3 4 5 5 6 6 7 8 9 10 11 11 12 13 14 15 16 17-18 Important Notice Safely Operating Gate Configuration and Specifications Warnings and Precautions Step 1: Getting Started Step 2: Mounting Operator Step 3: Chain Installation Step 4: Gate Movement Direction Step 5: DC Power Supply Connection Step 6: “Optional” Solar Panel Step 7: Terminal Connections Step 8: Adjusting Gate Travel Distance Step 9: Timer Step 10: 2-Way Adjustable Reversing Sensor “Optional” Input Board Master an
I M P O R T A N T N O T I C E IMPORTANT! Because gate coasting distance varies with temperature, Elite DOES NOT recommend the installation of a catch post. This could cause the gate to collide with the post.
S A F E L Y O P E R A T I N G G A T E Owners Must Never Let Pedestrians Cross the Path of a Moving Gate! CAUTION Owners Must Never Mount Any Gate Operating Devices Accessible In Between the Gate and the Wall! CAUTION CAUTION Owners Must Never Mount Any Gate Operating Devices Accessible Through the Gate!
C O N F I G U R A T I O N A N D S P E C I F I C A T I O N S Elite's Recommended Gate Setup Configuration Warning Signs on Both Sides of Gate Guide Rollers 3" Maximum Picket Width 2"x 2" Mesh Wire Across Entire Gate Guide Rollers Over-Travel Stops on Both Ends of Gate Rail Steel V-Groove, High Speed Ball Bearing Wheels Warning Sign Clearly Visible on Gate Operator 18 VAC Plug-In Transformer, for Each Gate Operator Reinforced Concrete to Bolt Operator on U.L.
R E A D E N T I R E O W N E R S M A N U A L B E F O R E I N S TA L L AT I O N Model: Robo Slide DO NOT Use for For Single Home Applications. Apartment or Condominium Applications. PLEASE DO NOT REPAIR ME!...UNLESS YOU ARE AN AUTHORIZED SERVICE TECHNICIAN! Warnings and Precautions CAUTION 1. Do not tighten chain too tight 2. Use proper type of wheels - only 4" steel wheels with high speed ball bearings 3. Do not use a 12V transformer - use only 18 VAC 2.0 Amp 4.
S T E P B Y S T E P I N S T A L L A T I O N STEP 2: Mounting Operator Pour concrete bed for Robo Slide. Minimum size of bed is 20" x 15" x 20"d. Suggested installation for bolts is 1/2" x 3 1/2" (for red-head fastener).
S T E P B Y S T E P I N S T A L L A T I O N STEP 4: Gate Movement Direction Plug in the limit/motor harness wires to the left socket (#1) if your gate, from the inside of the property, opens to the left and closes to the right. Plug into the right socket (#2) if the gate opens to the right and closes to the left from the inside of the property.
S T E P B Y S T E P I N S T A L L A T I O N STEP 5: DC Power Supply Connection Use Elite's optional 18 VAC plug-in transformer (Elite Part # A POW-1). Hook up the transformer to 115 VAC. Use two, low voltage, 14 gauge / 300watt direct burial, landscape lighting cables. Hook these wires to the two yellow wires from the control board to the plug-in transformer. CHECK CHARGINGFUSE BOARD POWER POWER SYSTEM ON J2 ALARM SENSOR CAUTION Do Not use solar panel and plug-in transformer at the same time.
S T E P B Y S T E P I N S T A L L A T I O N STEP 6: Optional Solar Panel Connection If you use Elite's optional solar panel (Elite Part # Solar 3). Connect the two wires from the solar panel to the two yellow wires on the control board. Sunlight will energize the batteries through the solar panel. This solar panel will charge up to 2800 Mamp/Hr in optimum conditions & 500 Mamp/Hr in light overcast conditions. For detailed specifications consult the Solar 3 Installation sheet.
S T E P B Y S T E P I N S T A L L A T I O N STEP 7: Terminal Connections The radio receiver must be 12 VDC only (Elite Part # A 1099-12V). If you want to use safety or exit loops, you must use 12 VDC loop detectors only (Elite Part # A 23). The hook-ups for the radio receiver are as follows: Strike open wires go to 8 and 9 on terminal. Power supply goes to terminal 10 (positive +) and terminal 8 (negative -). Connections for other devices are shown below.
S T E P B Y S T E P I N S T A L L A T I O N STEP 8: Adjusting Gate Travel Distance Adjustment is done by limit switches which are located on the Robo Slide chassis. By pressing the plate down and spinning the adjustment nuts, set your limit switches for open and close cycles. Limit Switches Each notch of the nut indicates an estimated 1 inch of gate travel STEP 9: Timer If you want to use the automatic close for the gate system the timer switch should be put in the “ON” position.
S T E P B Y S T E P I N S T A L L A T I O N STEP 10: Two-Way Adjustable Reversing Sensor There is a blue pot with a white screw adjustment on the upper portion of the control board marked “REVERSE SENSOR”. Do Not Touch Alarm Sensor blue pot. The level of sensitivity has to do with the weight of the gate and the condition of installation. Too sensitive = if the gate stops or reverses by itself. Not sensitive enough = if the gate hits an object and does not stop or reverse.
“ O P T I O N A L ” I N P U T B O A R D The optional board allows extra control of the gate, is available only from Elite Access Systems. Installation is simple; just clip the optional board to the J2 slot on the top of the control board. Below lists the function of each pin.
M A S T E R A N D S L A V E W I T H T I M E R To use the master/slave option with Robo Slide, you must purchase the Optional Input Board (Elite Part # Q203) and connect it to the J2 slot.
M A S T E R A N D S L A V E W I T H O U T T I M E R To use the master/slave option with Robo Slide, you must purchase the Optional Input Board (Elite Part # Q203) and connect it to the J2 slot.
C O N T R O L B O A R D F U N C T I O N S 1 Power on LED 2 Charge on LED 3 Low battery indicator LED 4 Heavy gate indicator LED 5 Open Relay LED 6 Close Relay LED 7 System on, Reversing sensor and Alarm sensor 8 Alarm sensor LED 9 Reversing sensor LED (Rebounder) 10 Central control LED 11 Fire department or key switch LED 12 Strike open LED 13 Safety loop or photocell LED 14 Exit loop LED 15 Radio receiver LED 16 Timer power LED 17 Timer-Up indicator 18 J2 alternate optional output 19 Movement direction
L E D LED Description 1 Power at all times when there is one or more power sources ie: Battery, 18 VAC or solar 2 Charger OK on when there is any charging power ie: 18 VAC - solar 3 Battery Low normally off - it will indicate low battery 4 Heavy Gate will work only when the gate is in motion D E S C R I P T I O N LED On Power source OK and board power fuse OK LED Off 1. No power source at all If dimmed down 1. Bad board power fuse 1.
L E D D E S C R I P T I O N LED Description 9 Reversing Sensor - C O N T I N U E D LED On LED Off Sensor is detecting obstruction No obstruction is detected Acknowledgement of receiving open command from one of the terminals 10 Central Control • Fire Department • Strike Open • Safety Loop • Exit Loop • Radio Receiver 1&2 3&4 5&6 7&8 8&9 Not receiving any command 11 Fire Dept Receiving signal at terminal block 1 & 2 Not receiving signal at terminal block 1 & 2 12 Strike Open Receiving signa
T R O U B L E S H O O T I N G How to Reset the Breaker If all electronic sensors fail or are not adjusted properly due to heavy gates, off-track gate, or obstructed gate path, the breaker will kick-out. Reset the breaker by pressing the reset button located on the bottom left corner of the control board. Always disconnect the battery before resetting the breaker or injury could CAUTION occur as the gate starts.
T R O U B L E S H O O T I N G The Gate Will Not Close! DC OPERATOR v 5M MADE IN USA CENTRAL CONT ROL FIRE DEPT STRIKE OPEN PW SAFETY LOOP 0 EXIT LOOP RADIO REC Symptom: The radio receiver LED on the control board remains “ON” when using the remote control. Possible Solutions: Stuck remote control button. The radio receiver has malfunctioned in the “ON” position.
T R O U B L E S H O O T I N G a n d P A R T S L I S T If you hear a “BEEP” sound, the gate is too heavy. If not check below. ALARM SENSOR 1 Debris is on the gate's track such as mud, rocks dirt, etc. 2 The gate is hitting a wall or a car. ALARM SENSOR 3 The gate has one or more broken wheels. ALARM SENSOR ALARM SENSOR 4 A car has hit the gate and the gate is off the track. After fixing the problem, the Robo Slide will automatically reset itself.
R O B O S L I D E P A R T S CHECK CHARGINGFUSE BOARD POWER POWER SYSTEM ON J2 Q206 ALARM SENSOR REVERSE SENSOR HEAVY GATE OVERLOAD POWER CHARGE OK BATTERY LOW DC OPERATOR v 5M MADE IN USA OPEN RELAY CLOSE RELAY CENTRAL CONTROL FIRE DEPT STRIKE OPEN UP TIMER PW SAFETY LOOP ON Q211 60 0 OFF EXIT LOOP RADIO REC W1 OPEN TO RIGHT Q218 Battery Harness Q204 Conversion Kit Q203 CHECK CHARGINGFUSE BOARD POWER POWER SYSTEM ON J2 ALARM SENSOR REVERSE SENSOR HEAVY GATE OVERLOAD Q162 P