INFRARED REFRIGERANT LEAK DETECTOR Security Precautions 1. Must read and be fully understood before proceeding with operation and maintenance. Pls read and fully understand this manual before operating and repairing. 2. Before performing the test, make sure there is a filter and it's clean, otherwise it will damage the sensor. 3. Before using the instrument, make sure that there is sufficient power to do this measurement work. 4.
INFRARED REFRIGERANT LEAK DETECTOR Table of Contents Safety Precautions First, the product description ee envenom 1.1 Product Overview eee 3 1.2 detailed parameters 3 1.3 ACCESSORIES mmm mmm Second, the Instrument Operation 5 2.1 panel display oo § 2.2 key operation -2.3 leak detection ee eee 6 24 charge =r] Third, after sales service and maintenance 8 3.1 ACCESSORIZES mmm mmm 8 3.
INFRARED REFRIGERANT LEAK DETECTOR First, the product description 1.1 Product overview The LID-100 is a hand-held leak detector that uses the infrared detection principle. Compared with the traditional leak detector, its sensor has longer life, higher detection accuracy, easy to operate and can detect a wider range of refrigerant. LID-100 is equipped with large TFT LCD screen, so that the test results are more intuitive.
INFRARED REFRIGERANT LEAK DETECTOR 1.2 Detailed parameters Sensor principle: Infrared spectrum absorption Sensor life: 10 years Sensitivity: max 4g / yr Alarm mode: sound and light alarm, TFT LCD display Automatic shutdown: 10 minutes without operation Battery: built-in rechargeable lithium battery 3.7V 3000mAh Working time: continuous 6H Charging: 4 hours Operating environment: relative humidity (50% ~ 85% RH) Storage temperature: 60°C 140 °F) Weight: 415g (14.
INFRARED REFRIGERANT LEAK DETECTOR Second, instrument operations 2.1 Panel display 1. The power indicator: real-time instructions battery allowance 2, Buzzer mute indication: indicates the buzzer status, When opening the buzzer status in green, closing status in red 3. The current leakage indicator: indicates the current leakage 4. Fault alarm: When the sensor failure, a fault indicator shows up 5. Warm-up countdown: warm-up time is 30 seconds.
INFRARED REFRIGERANT LEAK DETECTOR Switch key: press the button for 2 seconds to turn the instrument on or off. Mute key: press the mute button to turn on and off the buzzer Sensitivity adjustment key: press the sensitivity adjustment button to choose Low, Medium, High three different sensitivity levels TFT LCD display relative sensitivity level. 2.3 leak detection Test Precautions: LID-100 can detect relative concentrations. When the gas concentrations not change, it cannot detect the leakage.
INFRARED REFRIGERANT LEAK DETECTOR 4 The abnormal point of refrigerant pipe's cross section 4 The abnormal points of refrigerant pipe’s longitudinal section # Visual tracking of the entire refrigeration system (all piping, hoses, fittings, couplings, service valves, etc.) looking for lubrication oil leakage, damage and corrosion signs, If it is present, may be a leak point. 2.3.5 Slowly move the probe (approximately 3 inch/sec or 75 mm/sec) at a distance of 0.25 inch (0.63 cm) near the suspected leak area.
INFRARED REFRIGERANT LEAK DETECTOR Charging current: SVN 1A When the battery is charged, the power indicator is as follows, Charging status indication Red light: charging Blue light: charge is complete Third, aftermarket and maintenance Frequently Asked Questions and Solutions Phenomenon Solution When Error is displayed Sensor failure, replace the filter 3.1 Replace the filter element Filter can filter large particles of pollutants and steam, reduce the false alarm caused by excessive humidity of product.