INSTALLATION AND OPERATION MANUAL WHIRLPOOL, AIR BATHS AND SOAKING TUBS MODEL NUMBERS: 015-0005 015-0015 015-0026 015-0066 015-0076 015-0077 015-0140 015-0141 015-0142R 015-0142L 015-0143 015-0144 015-0145 015-0146 015-0150 015-0156 015-0305 015-0309 015-2500 015-4800 015-5400 025-0005 025-0140 025-0141 025-0142R 025-0142L 025-0143 025-0144 025-0145 025-0146 025-0155 025-0159 025-2505 025-4805 025-5405 035-0140 035-0141 035-0142R 035-0142L 035-0143 035-0144 035-0145 035-0146 035-0151 035-0158 035-2501 03
TABLE OF CONTENTS: Cover................................................................................................Page 1 Table of Contents..............................................................................Page 2 Safety Instructions Notice.................................................................Page 3 Installation, Framing and Post Installation Clean-Up Instructions.......................................................................
IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS READ AND FOLLOW ALL INSTRUCTIONS! ! WARNING: Risk of personal injury. Do not permit children to use this unit without adult supervision. ! WARNING: Risk of personal injury. Do not operate this unit without the guard over the suction fitting. ! WARNING: Risk of electric shock. Do not permit electrical appliances (hair dryer, telephone, radio, etc.) within 60 inches (1524mm) of this unit.
Installation and Framing Instructions Each bath arrives ready for installation, completely equipped with the pump and plumbing necessary for operation. However, a drain/overflow kit is required for each bath and it is not included. The variety of installations for this bath may require framing procedures other than those shown. Locate studs as required. Ensure roughing-in dimensions are proper, plumb, and square. ! ! Remove the bath from the carton.
INSTALLATION AND FRAMING INSTRUCTIONS The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs as needed. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an access opening for servicing the pump and controls. It is strongly recommended that an additional opening be provided for access to the drain components. The apron should not be used as the primary access opening. 1.
TYPICAL FLANGE MOUNTING DETAIL SUGGESTED WHIRLPOOL / BATH INSTALLATION METHOD WOOD STUDS STUD WATERPROOF DRYWALL OR CEMENT BOARD TILE ROOFING NAIL SEALANT TUB 1 x 3 (25 x 76mm) WOOD STRINGER FULL LENGTH STEEL STUD STEEL STUDS WASHER WATERPROOF DRYWALL OR CEMENT BOARD TILE SEALANT 4" (102mm) DRYWALL SCREW TUB 1 x 3 (25 x 76mm) WOOD STRINGER FULL LENGTH SECURE THE BATH TO THE STUDS AS SHOWN FOR WOOD OR STEEL STUD CONSTRUCTION.
SPECIFICATIONS: L W J H SIDE VIEW C A END VIEW B DRAIN / OVERFLOW GENERAL SPECIFICATIONS FOR ELJER WHIRLPOOLS AND BATH TUBS Description Dimensions L-W-H Drain / Overflow Height to Underside of Deck: C Cut Out Pier GxF Rough-In Recess ExD Tub Edge to Centerline Overflow: J Weight with Water / Floor Loading Product Weight Gallon to Overflow 015-0005 5' x 32" Cypress L 60" (1524mm) W 32" (813mm) H 18-1/2" (469mm) A 16" (406mm) B 10-1/4" (260mm) C 17-1/2" (445mm) 58-1/2" (1486mm) x 30-1/
SPECIFICATIONS: L W J H SIDE VIEW C A END VIEW B DRAIN / OVERFLOW GENERAL SPECIFICATIONS FOR ELJER WHIRLPOOLS AND BATH TUBS Description Dimensions L-W-H Drain / Overflow Height to Underside of Deck: C Cut Out Pier GxF Rough-In Recess ExD 025-0005 5' x 32" Cascada L 60" (1524mm) W 32" (813mm) H 19-1/2" (495mm) A 15" (381mm) B 10-1/4" (260mm) C 18" (457mm) 58-1/2" (1486mm) x 30-1/2" (775mm) 60-1/8" (1527mm) x 30-1/2" (775mm) 025-0140 5' x 32" LaSalle L 60" (1524mm) W 32" (813mm) H 20" (
ROUGH-IN REFERENCES CYPRESS MODEL 015-0005 60" (1524mm) 0/I 16" (406mm) 40-1/2" (1029mm) 32" (813mm) 19-1/2" (495mm) 9" x 14" (229 x 356mm) FLOOR CUTOUT PROVIDE ACCESS TO PUMP 10-1/4" (260mm) 1-1/2" (38mm) 60" (1524mm) 32" (813mm) 19" (483mm) 17-1/2" (445mm) MADISON MODEL 015-0015 60" (1524mm) 0/I 16" (406mm) 40-1/2" (1029mm) 32" (813mm) 19-1/2" (495mm) 9" x 14" (229 x 356mm) FLOOR CUTOUT PROVIDE ACCESS TO PUMP 1-1/2" (38mm) 60" (1524mm) 32" (813mm) 17-1/2" (445mm) 9 10-1/4" (260mm) 19"
ROUGH-IN REFERENCES CANTERBURY MODEL 015-0026 60" (1524mm) 18" (457mm) 44-1/2" (1130mm) 36" (914mm) 24-1/2" (622mm) 9" x 14" (229 x 356mm) FLOOR CUTOUT PROVIDE ACCESS TO PUMP 8-1/4" (209mm) 60" (1524mm) 1-1/2" (38mm) 36" (914mm) 19-1/2" (495mm) 17-1/2" (444mm) TRIANGLE MODEL 015-0066 35-1/2" (902mm) 60" (1524mm) PROVIDE ACCESS TO PUMP 35-1/2" (902mm) 46" (1168mm) 25-1/4" (641mm) 9" x 14" (229 x 356mm) FLOOR CUTOUT 10-1/2" (267mm) 0/I 48-5/8" (1235mm) 1-1/2" (38mm) 60" (1524mm) 44" (1118mm
ROUGH-IN REFERENCES EMBLEM MODEL 015-0076 EMBLEM TOTAL MASSAGE MODEL 015-0077 72" (1829mm) 0/I 18" (457mm) 51-1/2" (1308mm) 36" (914mm) 21-1/2" (546mm) 9" x 14" (229 x 356mm) FLOOR CUTOUT PROVIDE ACCESS TO PUMP 72" (1829mm) 1-1/2" (38mm) 36" (914mm) 10-1/2" (267mm) 19-1/2" (495mm) 17-1/2" (445mm) PATRIOT MODEL 015-0309 / 0305 (Right hand version shown) 60" (1524mm) 16" (406mm) 42" (1067mm) 32" (813mm) 18" (457mm) 9" x 14" (229 x 356mm) FLOOR CUTOUT PROVIDE ACCESS TO PUMP SERVING ON ALL INSTA
ROUGH-IN REFERENCES CABRILLO MODEL 025-0142R/L 38-1/2" (978mm) 16" (406mm) 19" (483mm) 32" (813mm) 32" (813mm) 60" (1524mm) 9-1/2" (241mm) 20-1/2" (521mm) CASCADA MODEL 025-0005 60" (1524mm) 0/I 16" (406mm) 32" (813mm) 40-1/2" (1029mm) 19-1/2" (495mm) 9" x 14" (229 x 356mm) FLOOR CUTOUT PROVIDE ACCESS TO PUMP 10-1/4" (260mm) 1-1/2" (38mm) 60" (1524mm) 32" (813mm) 18" (457mm) 754764-100 Rev.
ROUGH-IN REFERENCES LASALLE MODEL 025-0140 38-1/2" (978mm) 16" (406mm) 20" (508mm) 32" (813mm) 9-1/2" (241mm) 32" (813mm) 60" (1524mm) 1-1/2" (38mm) 20" (508mm) LASALLE XL MODEL 025-0141 50-1/2" (1283mm) 18" (406mm) 23" (584mm) 36" (914mm) 36" (914mm) 72" (1829mm) 1-1/2" (38mm) 9-1/2" (241mm) 21" (533mm) 13 754764-100 Rev.
ROUGH-IN REFERENCES MERRICK MODEL 025-0144 7-3/4" (197mm) 2-3/4" (69mm) 3" (76mm) 44-1/2" (1130mm) 21-1/2" 26" (546mm) (659mm) 16" (406mm) 32" (813mm) 53-3/4" (1365mm) 3-1/4" (83mm) 59-3/4" (1518mm) 32" (813mm) 1-1/2" (38mm) 59-3/4" (1518mm) 19-1/4" (489mm) 17-1/4" (438mm) MERRICK XL MODEL 025-0145 8-1/4" (209mm) 3" (76mm) 4" (102mm) 51-1/2" (1308mm) 26" 30" (660mm) (762mm) 18" (457mm) 63-1/2" (1612mm) 3-1/4" (83mm) 72" (1829mm) 32" (813mm) 20-1/4" (514mm) 754764-100 Rev.
ROUGH-IN REFERENCES GEMINI MODEL 025-0143 60" (1524mm) 60" (1524mm) 35-1/2" (902mm) 25-7/8" (657mm) 10-1/2" (267mm) 48-1/4" (1226mm) C/L OF OVERFLOW 1-1/2" (38mm) 3" (76mm) 21-1/2" (546mm) 18" (457mm) 20" (508mm) RIDGEFIELD MODEL 025-0146 7-3/8" (187mm) 4" (102mm) 4" (102mm) 42-1/2" (1079mm) 24" (609mm) 38" (965mm) 30" (762mm) 19" (482mm) 4" (102mm) 50" (1270mm) 38" (813mm) 20-1/4" (514mm) 2" (51mm) 23-1/2" (597mm) 58" (1473mm) 58" (1473mm) 21-1/2" (546mm) 15 754764-100 Rev.
ROUGH-IN REFERENCES VENICE MODEL 025-2505 21" (533mm) 42" (1067mm) 25-1/2" (648mm) Pump Location 45" (1143mm) 10-3/4" (273mm) C 36" (914mm) C = Control Panel 1-1/2" (38mm) 72" (1829mm) 42" (1067mm) 21-1/2" (546mm) 23" (584mm) GENESIS MODEL 025-5405 42" (1067mm) 24" (610mm) Pump Location 47" (1194mm) 10" (254mm) C 35-3/4" (908mm) C = Control Panel 1-3/4" (44mm) 71-1/2" (1816mm) 42" (1067mm) 20-1/4" (514mm) 18-1/2" (470mm) 754764-100 Rev.
ROUGH-IN REFERENCES PATRIOT MODEL 025-0155 / 025-0159 18" (457mm) 42" (1067mm) 18" (457mm) 36" (914mm) PUMP LOCATION C C = CONTROL PANEL 60" (1524mm) 36" (914mm) 1" (25mm) 21" (533mm) 18-3/4" (476mm) 16-1/4" (413mm) 19-3/4" (502mm) 1/2" (13mm) CASANOVA MODEL 025-4805 36" (914-mm) 60" (1524mm) 34" (864mm) 45" (1143mm) PUMP LOCATION 10-3/8" (264mm) C C = CONTROL PANEL 1-1/2" (38mm) 84-1/2" (2146mm) 60" (1524mm) 17-1/2" (445mm) 19-1/2" (495mm) 21" (355mm) 42-1/4" (1073mm) 17 754764-1
ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes. WARNING: When using electrical products, basic precautions should always be observed, including the following: 1. DANGER: RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground-fault circuit interrupter. 2. Grounding is required. The unit should be installed by a licensed electrician and grounded. 3.
ELECTRICAL INSTALLATION INSTRUCTIONS (continued) WHIRLPOOL PLUS AIR BATH COMBINATIONS The whirlpool pump and blower should be installed on a 120 vac, 20 amp dedicated circuit. The circuit should be hard-wired from the electrical power supply panel. The circuit must be a three (3) wire circuit from the electrical supply panel. A grounded neutral wire and a third wire, earth ground, are essential.
OPERATING INSTRUCTIONS 1. Fill the bath to at least 3 inches above the jets before activating the pump. 2. The pump is activated by an on/off switch. Each depression of the button switches the power either on or off. Do not repeatedly depress the switch in rapid order if you do not see the whirlpool function right away, as it may take a few seconds before you can see it fully operating. 3. If any factory installed fittings are removed do not operate the unit. A safety hazard may occur. 4.
Your Eljer whirlpool is designed to give you many years of pleasure with reasonable care and maintenance. Your new acrylic bathtub is tough, durable and easy to care for. The colors have been formulated to match other Eljer fixtures and enhance your choice of bathroom decorations. The high gloss surface will retain its lasting luster with proper care and maintenance. CLEANING AND MAINTENANCE: • Always fill the tub with temperate water. Excessively hot water (greater than 130˚ F) may cause surface damage.
AS AMERICA, INC. LIMITED LIFETIME WARRANTY FOR ELJER PREMIERE SERIES ACRYLIC TUBS, WHIRLPOOLS AND AIR BATHS AS America, Inc. (“American Standard”) warrants to the original consumer purchaser that it will, at its option, repair or replace this tub or any of its parts that are found by American Standard, in its sole judgment, to be defective under normal residential use and maintenance so long as it is owned by the original consumer purchaser. This limited warranty does not apply to commercial installations.