Installation manual

M1EZ8 Installation and Programming
Page 16
3-Walk Test Area r
< Area? Name >
4-View History r
Log
6-Change r
User Codes
Requires Master or
Installer Code
Menu 3 permits a local walk test of all zones assigned to this keypad’s area. The siren(s) and
communicator are disabled during a walk test. Press the RIGHT arrow key to begin a Walk
Test. The keypad displays the total tested zones adjacent to the total number of zones involved.
When a zone is activated, it’s name is displayed across the bottom and can be audible if the
Chime mode is on.
Allows viewing of the past 512 activities stored in the history log. Press the RIGHT arrow key to
view. History activities include: Arm, Disarm, Alarm, Trouble, etc. The top line displays the Log
number, Mth/Day, Time, and event description. The log can ONLY be cleared from ElkRP.
L001 is always the most recent event. Press the UP or DOWN arrow keys to move forward and
back. Event 512 will be the oldest event. The bottom line displays the event description, the
extended data (zone, user, etc.) and the area number (A1-A8).
Allows viewing of the current status of all zones. Press the RIGHT arrow key to select. Press
UP or DOWN to scroll through the zones or enter a three digit number to jump directly to a
particular zone. I.E. for zone 16 enter 016. Press the * key to exit.
For changing a user code and/or name for codes which have been previously enabled by the
Installer. There are a total of 99 user codes. Only a Master code OR the installer code can
access this menu. Press the RIGHT arrow key to begin. Press UP or DOWN keys to locate a
user, or enter 3 digits to jump. Press RIGHT arrow key to view the existing code. To change,
enter the new code digits and listen for 3 beeps to confirm. To edit the name, press the RIGHT
arrow key once, then press the DOWN arrow key. Enter the text using the letters on the keys.
I.E. For “K” press the 5 key twice. Move RIGHT or LEFT with the arrow keys. Press Chime to
insert a space. Press Bypass to erases a letter. The UP and DOWN arrow keys shift from
upper to lower case letters. Press the ELK key to save and exit.
.
Allows an end user to change up to 20 settings incorporated into an automation rule. These
settings can be: time of day, time duration (seconds), or a numeric value. Each custom setting
has a reference number (CS) and a text description: I.E. CS01: Sprkl On 00:00 [Time] implying
a time of day setting. Press the RIGHT arrow key to begin.
Press the UP or DOWN arrow keys to locate a setting, then press the RIGHT arrow key to
select. Enter the new value and press the ELK key to save and exit.
Menu 8 consists of 8 sub-menus used for advanced system settings. Press the right arrow key
and enter a valid user code. Press the UP or DOWN arrow keys to select a sub-menu or enter
the one digit number to jump directly to any sub-menu. I.E. enter 6 to jump to 86.
To set the system clock press the RIGHT arrow key, then press the UP or DOWN arrow key to
select the day. Next, press the RIGHT arrow key to move to Date/Time setting. Enter two digits
for month, date, year, hour, and min. To exit press the * key.
To set the volume for output 1 voice messages (non-alarm) press the RIGHT arrow key and set
desired volume with the UP or DOWN keys. There are 8 settings (0-7). WARNING: PROTECT
EARS! Each adjustment broadcasts a test message through Output 1. To exit press the * key.
To set keypad adjustments press the RIGHT arrow key. Then press the UP or DOWN keys to select
one of the three options.
8-System r
Settings
83-Keypad r
Adjustments
1:Set Keypad r
Beep Tone
2:Set Keypress r
Beep Volume
3:Set Backlight r
Dim Level
82-Out1 Voice
Adjust Volume r
81-Set Sys Clock r
24hr format
000of016 Tested r
A?-Violate Zones
L001:01/01
bb
bb
b08:00
AreaArmed 103A1
001:Sel
b b
b b
b Prgr
< User Name >
7--Automation r
Custom Settings
CS01:
bb
bb
b00:00Timer
Sprklr On
Requires Master or
Installer Code
Requires Master or
Installer Code
5-View Status r
of all zones
To set keypad beep tones press the RIGHT arrow key, then select the desired tone using the UP or
DOWN keys. There are 9 settings (0-8). When done, exit by pressing the * key.
To set key-press beep volume press the RIGHT arrow key, then select the desired volume using
the UP or DOWN keys. There are 7 volume levels (1-7) plus Off (0). To exit press the * key.
To set backlight dim level press the RIGHT arrow key, then select the desired level using the UP or
DOWN keys. There are 9 backlight levels (1-9) plus Off (0). The keypad automatically dims to this
setting after 30 seconds of no activity in order to save energy. To exit press the * key.