Menu 11 - Keypad F-Key Reporting Codes
11-Keypad F-Keyr
Reporting Codes
Press RIGHT arrow key to select this menu. Press UP or DOWN arrow keys to select
another menu. The ELK key backs up one menu level. To exit press the * or Exit key.
Referring back to Menu 04-Keypad Definitions, each F Key (F1 thru F6) can be programmed to activate a specific event.
If the programmed “activate event” is an alarm such as: Burg, Fire, Medical, Police Panic, etc., then it is possible to have
an alarm report code transmitted when an F key is used to activate that event. Enter a two digit value for the “A” alarm
report code. To disable the alarm report code enter 00. If the reporting format is SIA or Contact ID, the value can simply
be 01 because the control will automatically produces the correct code according to alarm type using the SIA or Contact
ID protocol. For 4+2 pulse format, enter a value from 01 to FF. To enter the A thru F HEX characters press the RIGHT
arrow key to position the cursor under the desired digit, then press the UP arrow (shift) key once. Each press of the 2
key will now produce the following: 2, A, B, C. Each press of the 3 key will now produce the following: 3, D, E, F.
Press the RIGHT arrow key to cancel shift and move to the next character.
FK01: A=00 r
[KP01 FKey01]
FK02:A=00 r
[KP01 FKey02]
F-Key Report Codes Description of Option
The ELK-M1KP Keypad has 6 programmable F keys while the ELK-M1KP2 Keypad has
just 4. This menu displays the F keys starting at FK01 thru FK06 for Keypad 1, then
FK07 thru FK13 for Keypad 2, etc. Use the UP and DOWN arrow keys to select the
appropriate keypad and key, then press the RIGHT arrow key to programming the code. It
may take some experimenting but it is possible to jump directly to a specific keypad and
key by entering a two digit number.
To program the alarm report code press the RIGHT arrow key to move the cursor into the
A= column, then enter a two digit value. Range is 00 to FF. Default is 00 (no report). To
return back to the left column to select another key or keypad press the ELK key
NOTE: Each reporting code must be programmed according to the desired reporting
format. However, for SIA and Contact ID formats the actual reporting digits will be
produced by the control according to the type of alarm or event. The only programming
required to enable reporting with the SIA and Contact ID formats is to set the programmed
code to a non zero (0) value. See below:
Alarms
Key Event Def. CID SIA
00 = Disabled ---- ----
01 = Burglar Entry/Exit 1 134 BA
02 = Burglar Entry/Exit 2 134 BA
03 = Burglar Perim Inst 131 BA
04 = Burglar Interior 132 BA
05 = Burglar Int Follower 132 BA
06 = Burglar Int Night 135 BA
07 = Burglar Int Nt Delay 135 BA
08 = Burglar 24 Hour 133 BA
09 = Burglar Box Tamper 137 TA
10 = Fire Alarm 110 FA
11 = Fire Verified 110 FA
12 = Fire Supervisory 200 FS
13 = Aux1 24hr Alarm 150 UA
14 = Aux2 24hr Alarm 150 UA
15 = Keyfob ---- ----
16 = Non-Alarm ---- ----
17 = Carbon Monoxide 162 GA
Based on the F Key Event definition, the CID (Contact ID) or SIA formats will be:
Alarms
Key Event Def. CID SIA
18 = Emergency Alarm 101 QA
19 = Freeze Alarm 159 ZA
20 = Gas Alarm 151 GA
21 = Heat Alarm 114 KA
22 = Medical Alarm 100 MA
23 = Police Alarm 120 P A
24 = Police No Indication 120 P A
25 = Water Alarm 154 WA
26 = Key Mom Arm/Disarm ---- ----
27 = Key Mom Arm Away ---- ----
28 = Key Mom Arm Stay ---- ----
29 = Key Mom Disarm ---- ----
30 = Key On/Off ---- ----
31 = Mute Audibles ---- ----
32 = Power Supervisory 338 YT
33 = Temperature ---- ----
34 = Analog ---- ----
NOTE: On CID reporting the 3 digit code will be preceded by a “1”.