Installation Guide

Page 6 ELK-6040 Glass Break Installation Manual
LIMITATIONS
While the 6040 Wireless Glass Break sensor is a highly reliable intrusion detection
device, it does not offer guaranteed protection against burglary. Any intrusion
detection device is subject to compromise or failure to warn for a variety of reasons:
Glassbreak sensors cannot consistently detect glass breaking around corners or in
other rooms.
The radio transceiver only provides communications. It does not have anything to
do with detecting the breaking of glass.
The 6040 Wireless Glassbreak is not a Life Safety device.
PO Box 100 3266 US Hwy 70 West
Hildebran, NC 28637
828-397-4200 828-397-4415 Fax http://www.elkproducts.com
Printed in USA
L649 Rev. A 8/7/2014
BATTERY WARNING: Risk of fire, explosion and burns. Do not attempt to
recharge or disassemble. Do not incinerate or expose to heat above 212°
F (100° C). Dispose of used batteries properly. Keep away from children.
FCC AND IC COMPLIANCE STATEMENT:
This device complies with Part 15 of the FCC Rules and Industry Canada License-Exempt RSS
Standards. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) This device must accept any interference received, including interference that
may cause undesired operation.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit
pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique
subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
ELK-6040 Wireless Glass Break FCC ID: TMAELK-6040
IC: 4353A-6040
NOTE: ELK PRODUCTS IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS
NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH
MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
LIMITED WARRANTY
The 6040 Wireless Glass Break Sensor is warranted to be free from defects and
workmanship for a period of 2 years from date of manufacture. Batteries used with
wireless devices are not warranted. Elk makes no warranty, express or implied,
including that of merchantability or fitness for any particular purpose with regard
to batteries used with wireless devices. Refer to Elk’s website for full warranty
statement and details.
9. MAINTENANCE
This product is design for a long service life. While the Control generally
provides indications when it is time to service this product, several annual
and random checks or tests are recommended.
Annual - Perform a Glass Break Functional Test
Random - Visually check that the Alarm LED flashes when
activated by the Wake Up Test
Besides Alarm indications the Control also provides Missing Transmitter
and Transmitter Low Battery indications.
Missing
Transmitter - The supervisory check-in signal from the sensor has
not reached the Control within the assigned
supervisory check interval. This could mean that the
sensor has been removed from the premises, or its
battery has been removed, or that it is experiencing
some other type of fault condition. Technical service
and/or corrective action is required.
Transmitter
Low Battery - The Battery voltage has reached a low voltage
threshold and must be replaced soon in order to
maintain proper operation.
In General
To keep this product in good working order:
- Vacuum or dust the cover of the product once a month to remove
accumulated dust.
- NEVER use detergents or solvents to clean the product. Chemicals
can permanently damage or temporarily contaminate the sensor.
- Avoid spraying air fresheners, hair spray, paint, or other aerosols
near the product.
- NEVER paint the product. Paint will seal the sensor opening and
interfere with proper sensor operation.
10. TROUBLESHOOTING
Product does not power up properly or reports low battery
- Check the battery to make sure it is fully seated within the
battery compartment and that the polarity is correct.
- Check the battery voltage (3.0 VDC nominal).
Control Panel does not respond
- Check the control panel programming to verify that the
sensor is enrolled (TXID number) and the zone is defined.
- Check another wireless sensor to see if the control
responds to it.
- Verify that the control and transceiver are powered up and
operating properly.
Alarm/open condition does not restore
- Check the battery and/or battery voltage.
- Does the sensor Alarm LED react to a Walk Up Test? (see
test Method #1 from section 8.1)
If so, remove the sensor cover and perform a Functional
Test (see test method #2 from section 8.2) while observing
the RF Status (ACKnowledge) LED. This will require a UTC
5709C (or equivalent) handheld glass break tester. Each
time the test is performed the RF Status LED should blink
once for the alarm transmission/reply, and a second blink a
few seconds later. This second blink is the sensor restoral
transmission/reply.
- Check the control panel programming to verify that the
sensor is enrolled (TXID number) and the zone is defined.
11. DELETING THE SENSOR FROM THE CONTROL
Deleting a sensor from the Control removes it from being monitored by the
customer’s system. This is not the same as bypassing a sensor. You
should delete a sensor only if it is being permanently removed from the
premises.
To delete a sensor from the Control there are three (3) steps in the Control
programming sections that must be addressed:
11.1 In the Zone Definitions menu locate the zone to which the sensor
belongs and change the Zone definition to "0 - Unused"
11.2 In the Wireless programming menu locate the "Enable Transmitter"
option for the sensor and uncheck (clear) that option.
11.3 In the Wireless programming menu locate the TXID for the sensor
and clear it (make it all zeros).
NOTE: If this sensor's zone was faulted (in a violated state) before it was
deleted then the zone will likely still be faulted. Exiting from the keypad
programming mode generally causes a restart and should clear the fault.
If it does not, power cycling the control is another way to clear it.