Installation Manual
ELK-M1XRF319 Installation Manual Page 7
ELK‐319DWMDoor/WindowMiniTransmitter>Notes:None>EnrollProcess:Removecoverandpulloutbatteryisolationtabstoapply
power.PressandreleaseTamperplungertosendenrollmenttopanel.>Options:SetOpt1&Opt2to0(no)>Loop:SetLoopto2
ELK‐319DRRecessedDoorTransmitter>Notes:Tochangebatteryremoveendcapbytwistingopen1/8"CCWusingacoinorscrewdriver.
Gentlygraspedgeofboardusingneedlenosepliersandpullout.>EnrollProcess:Removecoverandpulloutbatteryisolationtabtoapply
power.Placemagnettosensorandremovetosendenrollmenttopanel.>Options:SetOpt1&Opt2to0(no)>Loop:SetLoopto
2
ELK‐319WSWindowReed&ShockCombo>Notes:Thereedandshockeachrequireseparate(2)panelzones.TheprintedTXID#istheshock.
The reed is the same TXID # with the last digit increased by +1.The enrollment procedure and order determines which zone is 1
st
.> Enroll
Process:Toenrollbothsensorswiththeshockbeingthe1
st
zoneusetheinstructionspackedwiththesensor.Toenrollbothsensorswiththe
reedbein gthe1
st
zoneusethesesteps:1.Removecoverfromsensor.2.Startpanelenrollprocess.3.Holdonefingeronthetamperplunger
andthenremovethebatteryisolationtabstoapplypower.Keepfingerontamper!PanelshouldenrollthereedanddisplaytheprintedTXID#
+1digithigher.3.Ensurepanelenrollisadvancedtonextzone.4.Releasethetamperplunger.Panelshouldenrolltheshockasthe2
nd
zoneand
displaytheactualprintedTXID#.Options:SetOpt1&Opt2to0(no)>Loop:SetLoopto2forboth1
st
and2
nd
zone.
ELK‐319DGAllWeatherDoor&GateTransmitter>Notes:Twoscrewterminals permitanexternalN/O(normallyopen)switchtobeused
insteadofthebuilt‐inreed.>EnrollProcess:Removecoverandpulloutbatteryisolationtabstoapplypower.PressandreleaseTamperplunger
tosendenrollmenttopanel.>Options:SetOpt1&Opt2to0(no)ifusingbuilt‐inreedORSetOpt1&Opt2to1(yes)ifaexternalN/Oswitchis
connectedtothescrewterminals.>Loop:SetLoopto2ifusing built‐inreedORSetLoopto1ifusingscrewterminals.
REEDANDEXTERNALSWITCHARENOTDESIGNEDTOBEUSEDATTHESAMETIME.
ELK‐319KF1Single(1)ButtonPanic>Notes:ProgrammeddifferentlyfromaKeyfob.EG:ProgramM1zonedefinitionasthedesiredalarmtype.
Def:23=audiblePolice.>EnrollProcess:Pressandholdthebutton.>Options:SetOpt1&Opt2to0(no)>Loop:SetLoopto1
Additionalinfo:LEDflashesperiodicallytoletUserknowthebatteryisgood.Followinganalarmthezonewillremainviolated(PoliceTrouble)
untiltransmittersendshourlycheck‐inORuntilUsermanuallyresetszonebypressin gandholding thebuttonasecondtimefor~6sec.
ELK‐319PB1HeavyDuty1ButtonPanic>Notes:ProgrammeddifferentlyfromaKeyfob.EG:ProgramM1zonedefinitionasthedesiredalarm
type.Def:23=audiblePolice.>EnrollProcess:Pressandholdthebutton.>Options:SetOpt1&Opt2to0(no)>Loop:SetLoopto1
Additionalinfo:LEDflashesperiodicallytoletUserknowthebatteryisgood.Followinganalarmthezonewillremainviolated(PoliceTrouble)
untiltransmittersendshourlycheck‐inORuntilUsermanuallyresetszonebypressin gandholding thebuttonasecondtimefor~6sec.
ELK‐319KF4Four(4)ButtonKeyfob>Notes:ProgramM1zonedefinitionasKeyfob andassignbuttonactivationsviaM1Menu14,submenu4.
Icons:Button1=Lock,Button2=Unlock,Button3=Light,Button4=Asterisk.>EnrollProcess:Pressandholdbuttons1&2(Lock&Unlock)atthe
sametime.>Options:SettingOpt1to1(yes)willswapthe4buttonassignmentsfrom1thru4to5thru8.Opt2shouldbeleftas0(no).
>Loop:N/AAdditionalinfo:CombopressingtheLockandUnlockbuttonsatsametimewilltriggertheeventassignedtoKey7.Pressingthe
LightandAsterisktogetherwilltriggertheeventassignedtoKey8.
ELK‐319HRRHeatRateofRiseDetector>Notes:Toactivateamanualtestholdamagnetnexttomarkonfrontedgefor~15seconds.
>EnrollProcess:Pulloutbatteryisolationtabstoapplypowerandsendenrollmenttopanel.Iftheunitisalreadypoweredtrypushingand
releasingthetamper.>Options:SetOpt1&Opt2to0(no)>Loop:SetLoopto1
Part Number, Description, Notes, Enroll Process, Options and Loop ID Image
WhenusedwithElkM1Controlsthesetransmitters may be enrolledeitherfromKeypadInstallerProgramming(Menu14.Sub‐Menu3)usingthe
“Lrn”method,ORbyenteringtheTXIDthroughElk’sRPProgrammingSoftware.Carefullyfollowthespecifictransmitternotesoutlinedbelow.
IMPORTANT:Whenusingthesewithother319.5MHzpanelsitmaybenecessarytofollowenrollment proceduresofthatpanel.
ELK‐319PIRCCeilingMount360PIRSensor>Notes:Toconservebatterylifesensorhasa3‐minutesleepmodelockoutbetweenmotion
detectionsandtransmissions.Forwalktestingthe3‐minutelockoutmaybeavoidedbymomentarilyremovingsensorfromitsbase.Walktest
timesoutandendsafter1minuteofnomotion.>EnrollProcess:Pulloutbatteryisolationtabstoapplypowerandsendenrollmenttopanel.If
theunitisalreadypoweredtrypushingandreleasingthetamper.>Options:SetOpt1 &Op t2to0(no)>Loop:SetLoopto1
Elk Products 319.5MHz Transmitters