16. Measure 23 inches from the plug end of the power cord and place the strain relief on
the cord at that point. Fig. 9
17. Squeeze the strain relief and place in the slot in the bracket that the old power cord
was removed. Push up until it locks into place. Fig. 10
Fig. 10
Fig. 9
14. Using pliers, squeeze the strain relief on the power cord and pull down to remove the cord
from the bracket. Fig 8
15. Remove all remaining wires from the solenoid and cold control and discard.