Free Stone Fountain Owner's Manual

Page 497460C (Rev. SIB - 6/06)
4595_FTN
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
PRINTED IN U.S.A.
DESCRIPTION
100147140560
100322740560
101570540560
15005C
15013C
170705042830
40048C
40089C
400942308640
98287C
40169C
40250C
45476C
50986C
55913C
55996C
56092C
56121C
600985551640
61313C
66346C
70682C
70683C
75588C
75589C
1
2
3
4
5
6
7
8
9 - A
9 - B
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
PART NO.
Drain Gasket
Bubbler Gasket
Drain Gasket
Regulator Retaining Nut
Bubbler Tube Assy.
Basin
Button
Cover Nut
Bubbler
Bubbler Assembly
Hex Nut 1-5/16-20UN
Tailpipe 1-1/4" x 5-3/8"
Drain Tube
Regulator Holder
Drain Adapter
In-Line Strainer
Poly Tubing (Cut To Length)
Drain Elbow 1-1/4"
Drain Plug Assy.
Regulator
Drain Tube
Tee - 1/4
Union - 1/4
Slip Joint Nut 1-1/4"
Gasket
ITEM NO.
PARTS LIST
FIG. 6
NOTE: WATER FLOW
DIRECTION
BUILDING WATER INLET
SERVICE STOP
(NOT FURNISHED)
1/4" O.D. TUBE
WATER INLET
TO FOUNTAIN
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY
TROUBLE SHOOTING AND MAINTENANCE
Orifice Assy: Mineral deposits on orifice can cause water
flow to spurt or not regulate. Mineral deposits may be
removed from the orifice with a small round file or small
diameter wire. CAUTION: DO NOT file or cut orifice
material.
Stream Regulator: If orifice is clean, regulate flow as in
"STREAM HEIGHT ADJUSTMENT" instructions on page
3. If replacement is necessary, see parts list for correct
regulator part number.
Actuation of Quick Connect Water Fittings: Fountain is
provided with lead-free connectors which utilize an o-ring
water seal. To remove tubing from the fitting, relieve water
pressure, push in on the gray collar while pulling on the
tubing (See Fig. 5). To insert tubing, push tube straight
into fitting until it reaches a positive stop, approximately
3/4".
FIG. 5