Installation Sheet

PAGE 1298421C (Rev. C - 09/17)
HDFF-EBPFR*A HDFF-BLEBPFR*A HDFF-BLREBPFR*A
HDFF-BLREBP-FR WITH MPW200 MOUNTING PLATE
MOUNTING BOLT AND ACCESS HOLE LAYOUT
FIG. 11
28 9/16"
725mm
30 1/4"
768mm
43 1/2"
1105mm
3 1/4"
82mm
16"
406mm
32"
813mm
6 5/8"
168mm
18 3/4"
476mm
1 11/16"
43mm
1 11/16"
43mm
34 9/16"
878mm
36 1/4"
921mm
FINISHED FLOOR
HANGER BRACKET
BACK PANEL
MPW200
MTG. PLT.
A
A
B
B
C
C
D
12 1/8"
308mm
7 1/4"
185mm
12 1/8"
308mm
7 1/4"
185mm
12"
305mm
MAX. WALL
THICKNESS
1/2"
13mm
1/2"
13mm
1/2"
13mm
1/2"
13mm
LEGEND
A = 1-3/4" DIA. (44 mm) HOLE FOR WASTE LINE
B = 7/8" DIA. (22 mm) HOLE FOR WATER SUPPLY
C = 7/8" DIA. (22 mm) HOLE FOR OPERATING CABLE
D = 1/4" DIA. (6 mm) HOLE FOR MOUNTING PLATE TO WALL