Installation Sheet

12
DSBS130UVPC and DSBSH130UVPC
Installaon and Maintenance Manual
2. Cut, size and connect water and CO
2
piping to t your installaon.
NOTICE: The water pressure entering the machine must be between 14.5 psi (0.10 MPa) minimum and
51 psi (0.35 MPa) maximum. If the inlet water pressure is higher than 51 psi, the water pressure regulator
supplied must be used.
NOTICE: An incoming ow rate of >1.0 gallon/minute is recommended for opmal quality of sparkling
water.
NOTICE: Check all input piping and connecons for leaks before connecng to the machine.
Water source:
threaded
ng
Water
source: open
3/8" pipe
Water lter
3/8"
quick
connect
adapter
1/4” x 1/4”
Water shuto
valve
Water pressure
regulator
Water
piping cut
to size
1/4” Water
tubing cut to
size
To water
cooler
Short
3/8"– 3/8" pipe
Using the quick connect ngs
To connect:
1. Make clean, 90° cut to
piping end.
2. Push piping straight into
ng unl it stops.
3. Pull back to check that
connecon is secture.
To disconnect:
1. Press in the end tab.
2. Pull piping out.
3. Release tab.
1/4” Gas tubing
cut to size
Regulator
CO
2
source
1/4” water
tubing cut
to size
Recommended total
length 6 feet
Use one of two
connecon
methods
3/8” x 3/8”
quick connect
adapter
3/8” Tubing cut to
size if addional
length is needed
3/8" quick
connect
adapter