Problem Possible Cause Acon To Take
Poor sparkling water quality Incorrect air gap in the carbonator Close the CO
2
cylinder valve, pull up the ring
on safety valve (on the carbonator bowl head)
unl all air gap is out
Use of rinse aid or highly polished glass Avoid excessive use of rinse aid
The CO
2
regulator is set low Set the CO
2
regulator between 55-60 psi (3.5-
4 bar)
Water is not cold enough Set the thermostat properly
The incoming water pressure is too high Install an inlet water pressure reducer
(included)
The carbonator bowl is lled by the inlet high
water pressure and not by the pump
Install an inlet water pressure reducer
(included)
Incorrect inlet pressure Install an inlet water pressure reducer
(included)
The CO
2
cylinder is empty Replace the cylinder
The CO
2
valve is closed Open the valve
The seal is leaking Tighten regulator connecon at CO
2
tank
Replace seal
The CO
2
exit pressure lower than 36 psi (2.5
bar)
Set the pressure between 55-60 psi (3.5-4
bar)
A reset is needed Turn the machine o and back on
Problem Possible Cause Acon To Take
Only CO
2
gas comes out
when sparkling water buon
is pressed
The pump runs for 4 minutes connuously Check why the water is not entering the unit
and x it
The water valve is closed Open the valve
The lter is clogged Replace the lter
The main inlet water valve is closed Open the valve
The water inlet solenoid is not working Look for disconnected or loose wires
Replace the solenoid
The aluminium fusion block frozen Defrost the aluminium fusion block
Problem Possible Cause Acon To Take
Dripping water The solenoid is dirty Open the solenoid and clean it, use diluted
soluon for removal of mineral and calcium
buildup
Replace the solenoid
There’s sparkling water sll in the nozzle Clean the nozzle
Problem Possible Cause Acon To Take
Noise/Vibraon The copper tubing is vibrang against the
cabinet
Fix the posion of the the tubing
The fan is dirty Clean or replace it