Installation Guide

Activate the faucet
sensor (using your
hand), do not remove
from sensor motion area
until Step 8 is complete
.
Once all the air is purged
from the system, and
there’s a solid ow of water
from the faucet, turn o the
faucet by removing hand
from sensor motion area.
Verify water heater is ON
and set to recommended
“Ideal” heat setting.
Plug heater into GFCI
outlet and allow
30 minutes for water
in water heater to RISE to
SET temperature.
Check water temperature
by activating faucet with
motion to test temperature
of water. DO NOT USE SKIN
TO TEST TEMPERATURE.
Temperature should be
minimum 100 degrees and
maximum of 110 degrees.
If temperature needs
further adjustment,
adjust the mixing valve
inside the cabinet.
IF the ideal temperature
range still cannot be
reached after adjusting
the mixing valve, adjust
the setting on the
water heater.
HAVE TOUCHLESS HANDWASHING STATION QUESTIONS? REACH OUT - WE’RE HERE TO HELP - 800-260-6640
7
STEP
8
STEP
9
STEP
10
STEP
11
STEP
12
STEP
WATER HEATER SETTING DIAL
INDICATOR - SET TO “IDEAL”
IMPORTANT: PRIOR TO SETTING UP YOUR ELKAY UNIT, ENSURE YOU HAVE YOUR SITE
PREPPED. THIS INCLUDES ENVIRONMENT, WATER, AND ELECTRICAL SERVICE.
MIXING
VALVE
GFCI
OUTLET
WATER HEATER
ELECTRICAL CORD
(5/20) 1000005815