Installation Sheet

PAGE 3 98402C (Rev. A - 5/08)
EHWM14FP*A EHWM17FP*A
FIG. 2
1. Wall should already be framed for the fountain using dimensions shown in Fig. 1. Shown dimensions pertain to installation location.
These dimensions are required for compliance with ANSI Standard A117.1. and ADA (Framing shown for reference only).
2. Remove bottom cover from fountain and save the screws.
3. Install the fountain using bolts and washers (provided). Tighten securely.
4. Attach drain tube to fountain and cut to required length using the freeze resistant box as a guide.
5. Install freeze-resistant box - see box instructions.
6. Replace bottom cover.
EHWM14FP
ROUGH-IN DRAWINGS
* Adult ADA Requirement
**24" for Child ADA, adjust other
measurements accordingly.
2 5/8"
66mm
3 5/8"
91mm
12 3/8"
315mm
13 3/8"
340mm
16 7/8"
429mm
33"
838mm
Orifice Height
12"
305mm
MAX. WALL
THICKNESS
5/8"
16mm
18"
457mm
28"
711mm
18 3/4"
477mm
Finished Floor
27"
686mm
4 3/8"
111mm
3 13/16"
97mm
12 1/8"
309mm
19 3/4"
502mm
*
24 1/2"
622mm
20 3/8"
518mm