Specification Sheet

12 5/16"
313mm
27"
686mm
ADA
REQUIREMENT
2 9/16"
65mm
18 5/8"
472mm
1 3/8"
35mm
1 3/8"
35mm
5 3/4"
146mm
5 3/4"
146mm
4 9/16"
116mm
2 9/16"
65mm
7 1/4"
185mm
11/16"
18mm
2 7/16"
63mm
3 1/2"
89mm
4 1/2"
114mm
5"
127mm
10"
252mm
2 1/2"
64mm
13 7/8"
351mm
18 3/8"
467mm
21 3/8"
543mm
25"
635mm
3
1"
7
87mm
8"
202mm
6 1/4"
159mm
HANGER BRACKET
C
B
E
E
D
A
5/16" (8mm) DIA. (5 HOLES)
31 7/8"
810mm
F
33"
838mm
FINISHED FLOOR
6 3/4"
171mm
RATED FOR INDOOR USE ONLY
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER
ROUGH-IN DIMENSIONS
NOTICE
This water cooler must be connected to the water supply using a dielectric coupling.
The cooler is furnished with a non-metallic strainer which meets this requirement.
The drain trap, which is provided by the installer, should also be plastic to completely
isolate the cooler from the building plumbing system.
Open space rough-in design permits new installation or replacement of existing
fountains and coolers with this Elkay cooler when rough-in is within the outline shown.
IMPORTANT! INSTALLER PLEASE NOTE:
This water cooler has been designed and built to provide water to the user which has
not been altered by materials in the cooler waterways.
The grounding of electrical equipment such as telephone, computers, etc to water
lines is a common procedure. This grounding may be in the building or occur away
from the building. This grounding can cause electrical feedback into a water cooler
creating an electrolysis which creates a metallic taste or causes an increase in the
metal content of the water. This condition is avoidable by installing the cooler using
the proper materials as shown below.
LEGEND:
A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept
3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall.
B = Recommended Waste Outlet location. To accommodate 1-1/4” nominal drain.
Drain stub 2” (51mm) out from wall.
C = 1-1/4” Trap (not furnished).
D = Electrical Supply (3) Wire Recessed Box Duplex Outlet.
E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet
louvers to wall.
F = 7/16” (11mm) Bolt Holes for fastening to wall.
NOTE: New Installations Must Use Ground Fault Circuit Interrupter (GFCI)
Job Name: ____________________________________
Model: _______________________ Qty. ____________
Contact: ______________________________________
Approval Signature: _____________________________
Notes:
Printed in U.S.A.
© 2015 Elkay
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com
Non-Filtered
Wall Mount Water Cooler
Models EMABF8* and EMABFD*
Model shown with Flexi-Guard
®
bubbler.
B CA
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A B C
1/4” O.D. TUBE
WATER INLET
TO COOLER
3/8” O.D. TUBE CONNECT
COLD WATER SUPPLY
BUILDING WATER
INLET
NOTE: WATERFLOW
DIRECTION
SERVICE STOP
(NOT FURNISHED)