Specification Sheets

®
ROUGH-IN DIMENSIONS
Elkay Manufacturing Company
2222 Camden Court
Oak Brook, IL 60523
Printed in U.S.A.
©2012 Elkay Mfg. Co.
13-3E (Rev. 05/12)
No Lead Remote Chiller
Air Cooled
Model ER5
19-9/16"
(497 mm)
7-15/16"
(202 mm)
1-9/16"
(39 mm)
3/8" O.D. TUBING
COLD WATER OUT
3/8" O.D. TUBING
WATER INLET
7/8"
(22 mm)
ELECTRICAL
ADJ. COLD CONTROL
3/8" O.D. TUBING
TANK DRAIN
1-1/4"
(32 mm)
22-1/16"
(560 mm)
6-1/4"
(159 mm)
FRONT VIEW
TOP VIEW
SIDE VIEW
Drain Plug: This chiller is provided with a plastic drain plug which incorporates
an o-ring seal. This fitting is designed for potable water applications and should
be replaced with a suitable fitting if chiller is used with more aggressive liquids.
NOTE: It is important to insure proper ventilation. Allow a minimum clearance of
6 inches (152 mm) in front and 3 inches (76 mm) in the rear of the unit.
If unit is to be installed in an enclosure, allow the following clearances
around unit: 1 inch (25 mm) each side, 3 inches (76 mm) in the rear,
3 inches (76 mm) above. Wall grill, EG1 or EG2 may be used when unit
is inserted into an enclosure. A 6 inch (152 mm) clearance beyond the
front of the wall grill is required.