Specification Sheet

GENERAL
Two-level barrier-free stainless steel water cooler has
recessed in-the-wall refrigeration system and stainless steel
grill. All stainless steel polished to a satin finish.
Sensor-operated wheelchair fountain has unique Hands-
Free
®
operation and automatic flow regulators provide con-
stant stream from 20 to 105 psi. Vandal-resistant bottom
cover plates.
NOTE: Minimum 40 psi supply line pressure required in spe-
cial circumstances where both sides of bi-level are in use
simultaneously to ensure adequate stream height. Use of
water filter in this situation is not recommended.
Energy efficient refrigeration system utilizes a combination
tank continuous-tube type evaporator, refrigerant drier, and
capillary tube.
THIS WATER COOLER COMPLIES WITH THE REQUIRE-
MENTS OF A.D.A. (AMERICANS WITH DISABILITIES ACT)
WHEN PROPERLY INSTALLED. UNIT IS COMPLIANT IF
INSTALLED IN AN ALCOVE AND IS ALSO COMPLIANT
WHEN MOUNTED ON AN EXPOSED WALL IF A WING
WALL IS LOCATED ON THE LEFT SIDE OR IF A 97258C
APRON IS INSTALLED UNDER THE UPPER UNIT.
NO LEAD DESIGN
THIS WATER COOLER COMPLIES WITH THE LEAD-FREE
DEFINITION IN THE SAFE DRINKING WATER ACT OF
1986 AND LEAD CONTAMINATION CONTROL ACT OF
1988.
Elkay Water Coolers are manufactured with a waterway sys-
tem utilizing copper components and completely lead-free
material. These waterways have no lead because all lead
materials, such as leaded brass, have been removed. All
joints are brazed using silver solder only. No lead solder is
permitted. A strainer with an easily cleanable screen is pro-
vided to allow trapping and convenient removal of waterborne
particulate of 140 microns and larger prior to their entry into
the water cooler.
This water cooler is certified to NSF/ANSI 61.
COOLING SYSTEM
Motor Compressor: Hermetically sealed, reciprocating type,
115V, 60 Hz or 230V, 50 Hz (International Model) single phase.
Sealed-in lifetime oil supply.
Condenser: Fan cooled, copper tube with aluminum fins. Fan
motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Self cleansing. Tube
portion is continuous coil of copper tubing. Tank is stainless
steel. Fully insulated with EPS foam which meets Underwriters
Laboratories Inc. requirements for self extinguishing material.
Temperature Control: Enclosed adjustable thermostat is
factory preset. Requires no adjustment other than for altitude
requirements.
CAPACITIES CHART
*Based on 80°F inlet water temperature.
Rated watts shown are based on operational (run) time, in compliance with A.R.I.
Standard 1010 conditions. Specific applications will determine the actual watts
consumed per hour. Watts consumed will be based on number of people
served per hour (usage), ambient temperatures, and inlet water temperature.
*GPH of 50°F Drinking Water
Full Glass Ship.
Model Base
Room Temperature °F
Rated Load Filler Wt.
Number Rate 70°F 80°F 90°F Watts Amps Option Lbs.
EROM28K 7.5 8.6 8.1 7.5 370 4.0 No 136
Model EROM28K
Refrigerant Control: Refrigerant HFC-134a is controlled by
accurately calibrated capillary tube for positively trouble-free
performance.
CONSTRUCTION
Fountain Body: #18 gauge, type 304 nickel bearing stainless
steel polished to a lustrous satin finish with high shined outer
edge. Contoured basin offers large strike area to minimize
splashing.
Exclusive Flexi-Guard
®
Safety Bubbler**: Innovative design
utilizes an infused anti-microbial pliable polyester elastomer
to prevent accidental mouth injuries. Flexes on impact, then
returns to original position. Strong. Abrasion-resistant. Anti-
sweat. Keyed in location to prevent rotation.
ELECTRONIC SENSOR OPERATION
On-Off solenoid valve is actuated by an infra-red light beam
sensor. When light beam is interrupted by subject in front of
cooler desiring a drink, the sensor actuates the solenoid valve
which then opens to allow water to flow. No physical contact
with cooler is required. A built in time delay is provided to pre-
vent actuation by persons moving past cooler. There is a max-
imum running time of 30 seconds to prevent malicious
damage to the cooler or water damage if sensor vision is
blocked. Unit automatically resets when blockage is removed.
Front Panel Grill: Made of type 304 stainless steel, polished
to a uniform Elkay satin finish. Removable louvered ventilat-
ing grill encloses refrigeration unit and plumbing.
Wall Mounting Frame: MF200 frame furnished with each
unit. Frame allows flush mounting to finished wall.
Drain: LK464 drain and trap assembly included.
5 YEAR LIMITED WARRANTY on the refrigeration system of
the unit. Electrical components and water system are war-
ranted for 12 months from date of installation. Sample
Certificate available on request.
Elkay Pressure-Type Water Coolers are designed to operate
on 20 psi to 105 psi supply line pressure. If inlet pressure is
above 105 psi, a pressure regulator must be installed in the
supply line. Any damage caused by reason of connecting this
product to supply line pressures lower than 20 psi or higher
than 105 psi is not covered by the warranty.
STANDARDS
Elkay
2222 Camden Court
Oak Brook, IL 60523
Printed in U.S.A.
©2006 Elkay
(Rev. 1/06) 12-17F
elkayusa.com
In keeping with our policy of continuing product improvement, Elkay reserves the right to change
product specifications without notice.
This specification describes an Elkay product with design, quality and functional benefits to the
user. When making a comparison of other producers’ offerings, be certain these features are not
overlooked.
** Patent #4,481,971
Elkay Electric Air Cooled Water Coolers meet the
requirements of NSF/ANSI 61. Unit complies with
A.R.I. Standard 1010.
No Lead Two-Level Soft Sides
®
Sensor-Operated Hands-Free
®
Wall Mount
Water Cooler – Barrier-Free Access
Model EROM28K
®
SPECIFICATIONS

Summary of content (2 pages)