Instructions / Assembly

97153C (Rev. G - 8/16)
For Technical Service, please contact us at 1.800.476.4106
Elkay - www.elkay.com
Halsey Taylor - www.halseytaylor.com
37 3/4"
(959mm)
4 1/2"
(114mm)
18 3/4"
(476mm)
5 1/8"
130mm
BACK OF WALL TO
BE 12" (305mm)
MIN DEPTH
8"
(203mm)
TO FLOOR LINE
FLOOR LINE
WOOD OR STEEL FRAME SHOWN
(NOT PROVIDED)
ELECTRICAL INLET
LOCATION ON CHILLER
1 1/8"
(29mm)
(P/N 27638C
- PROVIDED)
(P/N 101567443730
- PROVIDED)
SCREWS OR BOLTS
(NOT PROVIDED)
5/16" SCREWS OR BOLTS
(10 REQ'D-NOT PROVIDED)
FRAME
IMPORTANT:
DOUBLE STUD OR 3 INCHES (76mm)
BETWEEN MOUNTING FRAMES
IF PLACED NEXT TO A BOTTLE
FILLER UNIT
(P/N 111008343890
- PROVIDED)
1. Cut a square rectangular wall opening 18 3/4” (476mm) W x 37 3/4” (959mm) H and 4 1/2” (114mm)
above the oor line. These dimensions are required to obtain proper rim and bubbler heights for
compliance with ANSI standard A117.1.
2. Reinforce the wall opening on all sides so that it will adequately support the water fountain. This
reinforcement must support up to 150 lbs static load and provide a means for securing the frame
assembly in place.
NOTE: Building construction must allow for adequate air ow on both sides and top of remote chiller
unit. Minimum of 4” (102mm) is required.
3. Install plumbing and electrical rough-ins. A junction box for a (3) wire, 10 amp branch circuit is
provided on the inside of the chiller. (Standard 120 Volts, 60 Hz and single phase)
4. Remove frame and related hardware from packaging. Release the two shelf rods by cutting cable ties.
Install the frame squarely in wall opening with frame upright edges ush with the nished wall face.
Place shelf inside frame and line up the (2) holes on each. Insert loose ends of rods into holes on sides of
shelf panel. Using appropriately sized screws or bolts (not provided), fasten the shelf and frame to bottom
of wall opening. Secure the frame sides and top to the wall using (10) 5/16” bolts or screws (not provided).
NOTE: Be sure that frame is squared in location. Do not use less than the required screw quantity and
size.
SINGLE-STATION MOUNTING FRAME INSTRUCTIONS
ACTUAL FRAME MAY VARY
FROM THE ONE ILLUSTRATED.
PLEASE REFER TO THE
INSTALLATION/OWNERS MANUAL
OF THE SPECIFIC UNIT FOR
ADDITIONAL INFORMATION.
MF100

Summary of content (2 pages)