EZFS8*1H, 2H, 3H LZFS8*1H, 2H, 3H EZFSD*1H LZFSD*1H INSTALLATION & USE MANUAL Manual de instalación y uso Manuel d’installation et utilisation EZ™ & LZ™ Series Barrier-Free Water Coolers EZ™ & LZ™ La Barrera de la serie Liberta Agua Coolers EZ™ & LZ™ Coolers d’Eau de Barrière-Libère de feuilleton Model EZS8L Page 1 1000002685 (Rev.
EZFS8*1H, 2H, 3H LZFS8*1H, 2H, 3H EZFSD*1H LZFSD*1H Note: Danger! Electrical shock hazard. Disconnect power before servicing unit. Nota: peligro! Peligro de descarga eléctrica. Desconecte antes de reparar la unidad Remarque : Danger ! Risque de choc électrique. Débrancher avant de réparer l’appareil.
Page 3 F 7" 178mm 2" 51mm 3 7/8" 98mm 28 13/16" 732mm 13 15/16" 354mm A E C 8 1/16" 205mm 12 1/2" 318mm 5 7/8" 150mm HANGER BRACKET FINISHED FLOOR 27" 686mm ADA REQUIREMENT 31 11/32" 796mm RIM HEIGHT 32 7/8" 835mm ORIFICE HEIGHT 2" 51mm 3" 77mm 2" 51mm EZFSD*1H REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDREN’S ADA COOLER 7" 178mm 5 3/4" 146mm C L 6 3/8" 162mm 19 1/32" 483mm LZFS8*1H, 2H, 3H LEGEND/LEYENDA/LÉGENDE A = RECOMMENDED WATER SUPPLY LOCATION 3/8” O.D.
EZFS8*1H, 2H, 3H HANGER BRACKETS INSTALLATION 1) Remove hanger brackets fastened to back of cooler by removing one (1) screw. 2) Mount the hanger brackets as shown in Figure 2. NOTE: Hanger Bracket MUST be supported securely. Add fixture support carrier if wall will not provide adequate support. Anchor hanger securely to wall using all six (6) 1/4 in. dia. mounting holes. INSTALLATION OF COOLER 3) Hang the cooler on the hanger bracket.
EZFS8*1H, 2H, 3H LZFS8*1H, 2H, 3H EZFSD*1H LZFSD*1H Service Instructions Lower and Upper Shroud To access the refrigeration system and plumbing connections, remove four screws from bottom of cooler to remove the lower shroud. To remove the upper shroud for access to the pushbars, regulator, solenoid valve or other components located in the top of the unit, remove lower shroud, disconnect drain, remove four screws from tabs along lower edge of upper shroud, unplug two wires and water tube.
EZFS8*1H, 2H, 3H LZFS8*1H, 2H, 3H EZFSD*1H LZFSD*1H NOTE: When installing replacement bubbler and pedestal, tighten nut only to hold parts snug in position. Do Not Overtighten. NOTA: Al instalar el grifo y pedestal de reemplazo, apriete la tuerca unicamente para mantener las piezas en una posicion adjustada. No dede apretarse demasiado.
EZFS8*1H, 2H, 3H LZFS8*1H, 2H, 3H EZFSD*1H LZFSD*1H 17 OVERLOAD BLK 3 1 2 COLD CONTROL C FAN 5 3 2 1 GREEN - GND 6 SOLENOID VALVE WHT RELAY (BLACK - L) 115V Wiring Diagram Esquema eléctrico 115V Diagramme de câblage 115V (WHITE - N) M S Fig. 7 GND 17 OVERLOAD 3 COLD CONTROL 2 WHT C 220V Wiring Diagram Esquema eléctrico 220V Diagramme de câblage 220V 6 5 3 2 SOLENOID VALVE GREEN - GND FAN Fig.
EZFS8*1H, 2H, 3H ITEM NO.