Instructions / Assembly

0000001029 (Rev. G - 04/18)
EDFPBM117WS EDFPBM117WS-F
Page 3
Figure 3 - LZWS-EDFPBM117K Tube Routing
REQUIRED TOOLS AND MATERIALS
These tables show special tools and/or additional materials
(not provided) which are necessary to complete installation
of these units:
12
12
25
TO BUBBLER
12
Figure 2 - EZWS-EDFPBM117K Tube Routing
TO BUBBLER
21
FILTER
ASSEMBLY
13
12
12
WATER
INLET
Special Tools
Item
Description
Quantity
NONE
Additional Materials Not Included
Item
Description
Quantity
Unplated copper inlet pipe
Service Stop/Shut-off Valve
90° 1-1/4” Drain Line
1-1/4” Tee Drain Line
1
2
3
4
1
1
1
1
WATER
INLET
TO BUBBLER
31
24
TO BOTTLE
FILLER
TO BUBBLER
26
13
31
14
TO BOTTLE
FILLER
1. Make water supply connections (Fig. 11). Install a shut-off
valve and union connection to building water supply (valve
and union not provided). Turn on water supply and ush
the line thoroughly.
Caution: DO NOT SOLDER tubes inserted into the
strainer or lter head as damage to the o-rings may result.
2. Install mounting frame (instructions supplied with mounting
frame.
3. (For LZWS-EDFPBM117K) Install the lter head to the bracket,
then install lter bracket on mounting frame (Fig. 10), plumb from
the lter outlet to the chiller inlet with ¼” elbow, poly tubing and
¼ x ¼ union, install lter.
3a. (For EZWS-EDFPBM117K) Install strainer on the input tube to
the chiller (Fig. 2).
4. Install ¼ x ¼ x 3/8 Tee on building water supply tube. Install
supplied 4” poly tubing and armaex to the outlet of the prev-
ously installed tee. Connect supplied ¼ x ¼ x ¼ tee to the 4” poly
tubing. With the back panel standing close to the frame, connect
3/8” poly tube to the bottle ller.
5. Hang main panel on mounting frame hanger. Make sure the
power cord, reset switch wire & poly tube do not get pinched
between the panel & mounting frame. Ensure the panel engages
at the top. Align fountain holes with mounting frame holes.
6. Remove protective coating from main panel.
7. Install reset switch for bottle ller (Fig. 5). Snap the switch into
position after locating wires through slot. Wrap up the excess
cord.
12