GENERAL
Self-contained, electric refrigerated floor model water cooler.
Capacity of 50°F drinking water, based upon 80°F inlet water
and 90°F ambient.
This model furnished with hermetically sealed combination
tank-tube type cooling unit enclosed in cabinet. Cabinet
design allows for flush to wall installation. Removable front
panel and cabinet sides are Sandal-wood Vinyl.
Non-pressurized tank system is standard. Non-pressurized
water tank is located after bubbler valve, so that tank is sub-
ject to line pressure only when valve button is pressed.
NO LEAD DESIGN
THIS WATER COOLER COMPLIES WITH THE LEAD-FREE
DEFINITION IN THE SAFE DRINKING WATER ACT OF
1986 AND LEAD CONTAMINATION CONTROL ACT OF
1988.
Elkay Water Coolers are manufactured with a waterway sys-
tem utilizing copper components and completely lead-free
material. These waterways have no lead because all lead
materials, such as leaded brass, have been removed. All
joints are brazed using silver solder only. No lead
solder is permitted. A strainer with an easily cleanable screen
is provided to allow trapping and convenient removal of
water born particulate of 140 microns and larger prior to their
entry into the water cooler.
This water cooler is certified to
NSF/ANSI 61.
COOLING SYSTEM
Motor Compressor: Hermetically sealed, reciprocating type,
115V, 60 Hertz single phase. Sealed-in lifetime oil supply.
Equipped with electric cord and three prong molded rubber
plug.
Condenser: Fan cooled, copper tube with aluminum fins.
Fan motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Tube portion is
continuous coil of copper tubing. Fully insulated with EPS
foam which meets Underwriters Laboratories Inc. require-
ments for self extinguishing material.
Refrigerant Control: Refrigerant HFC-134a is controlled by
accurately calibrated capillary tube for positively trouble free
performance.
Temperature Control: Enclosed adjustable thermostat is
factory pre-set. Requires no adjustment other than for alti-
tude requirements.
CONSTRUCTION
Cabinet: Cabinet wrapper supports fountain top and all
working mechanisms. Removable front panel and cabinet
sides are Sandalwood vinyl. Stainless Steel cabinet available
at extra cost.
Fountain Top: One piece stainless steel top, polished to a
uniform Elkay bright luster finish. Unique Swirl-Flo basin has
an integral vandal-resistant strainer, embossed bubbler pad.
Exclusive Flexi-Guard
®
Safety Bubbler*: Innovative design
utilizes an infused anti-microbial pliable polyester elastomer
to prevent accidental mouth injuries. Flexes on impact, then
returns to original position. Strong. Abrasion-resistant. Anti-
sweat. Keyed in location to prevent rotation.
5 YEAR LIMITED WARRANTY on the refrigeration system of
the unit. Electrical components and water system are war-
ranted for 12 months from date of installation. Sample
Certificate available on request.
Elkay Pressure-Type Water Coolers are designed to operate
on 20 psi to 105 psi supply line pressure. If inlet pressure is
above 105 psi, a pressure regulator must be installed in the
supply line. Any damage caused by reason of connecting this
product to supply line pressures lower than 20 psi or higher
than 105 psi is not covered by the warranty.
STANDARDS
Model FD7005
In keeping with our policy of continuing product improvement, Elkay reserves the right to change
product specifications without notice.
This specification describes an Elkay product with design, quality and functional benefits to the
user. When making a comparison of other producers’ offerings, be certain these features are not
overlooked.
* Patent #4,481,971
Elkay
2222 Camden Court
Oak Brook, IL 60523
Printed in U.S.A.
©2006 Elkay
(Rev. 7/06) 9-5F
elkayusa.com
No Lead Space-ette
®
Floor-Mounted and Flush to Wall Water Cooler
Models FD7003, FD7005 and FD70010
®
SPECIFICATIONS
Elkay Electric Air Cooled Water Coolers meet the
requirements of NSF/ANSI 61. Unit complies with
A.R.I. Standard 1010.
CAPACITIES CHART
**Based on 80°F inlet water temperature.
Glass filler available at extra cost. Requires factory preparation to receive glass
filler.
Rated watts shown are based on operational (run) time, in compliance with ARI
Standard 1010 conditions. Specific applications will determine the actual watts
consumed per hour. Watts consumed will be based on number of people
served per hour (usage), ambient temperatures, and inlet water temperature.
**GPH of 50°F Drinking Water
Full Glass† Ship.
Model Base
Room Temperature °F
Rated Load Filler Wt.
Number Rate 70°F 80°F 90°F Watts Amps Option Lbs.
FD7003
3.0 3.6 3.3 3.0 230 2.5 Yes 54
FD7005
5.0 6.1 5.5 5.0 230 2.5 Yes 60
FD70010
9.8 11.9 10.8 9.8 535 5.8 Yes 69