Specification Sheets

(305mm)
(114mm)
(305mm)
(102mm)
TOP VIEW
FRONT VIEW
(965mm)
(89mm)
(22mm)
(102mm)
(51mm)
(305mm)
(800mm)
(737mm)
O.D. TAILPIECE
WALL 1" (25mm)
WALL 1" (25mm)
LONG POWER CORD
SIDE VIEW
TRAP BY OTHERS
TANK DRAIN
Elkay
2222 Camden Court
Oak Brook, IL 60523
elkayusa.com
Printed in U.S.A.
©2013 Elkay
(Rev. 4/13)
No Lead Space-ette
®
Floor-Mounted and Flush to Wall Water Cooler
®
®
ROUGH-IN DIMENSIONS
NOTE: WATERFLOW
DIRECTION
SERVICE STOP
(NOT FURNISHED)
3/8" O.D. TUBE CONNECT
COLD WATER SUPPLY
1/4" O.D. TUBE
WATER INLET
TO COOLER
BUILDING WATER
INLET
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
AB
C
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A B
C
IMPORTANT!
INSTALLER PLEASE NOTE:
This water cooler has been designed and built to provide water to the
user which has not been altered by materials in the cooler waterways.
The grounding of electrical equipment such as telephone, computers,
etc., to water lines is a common procedure. This grounding may be
in the building but may also occur away from the building. This grounding
can cause electrical feedback into a water cooler creating an electrolysis
w
hich creates a metallic taste or causes an increase in the metal content
of the water. This condition is avoidable by installing the cooler using the
proper materials as shown below.
NOTICE
This water cooler must be connected to the water supply using a di-
electric coupling. The cooler is furnished with a non-metallic strainer
which meets this requiremen
t.
The
drain trap which is provided by the installer should also be plastic to
completely isolate the cooler from the building plumbing system.
Models FD7003, FD7005, FD70010 & FD700D