4.4.3 Connecting the Water Lines
1. Route a 1/4" water line from the water dispenser into
the lter housing outlet (located on the underside of
the lter head).
NOTICE
Do not disconnect the 1/4"
tubing from the water valve at
the top of the water dispenser. This connection has
been factory tested to be leak-free and could result in
water leaking into the unit if this connection is
changed.
2. Connect the NFC wire to the wire harness.
3. Connect the 1/4" tube to the tting below the lter, as
shown.
4. Connect an installer supplied 3/8" water supply tube
to the quarter-turn shutoff valve, as shown. The type
of tubing, copper or plastic, should meet all local
regulations and building codes.
Note: Elkay also recommends installing a shutoff valve
at the source of the water supply for the water
dispenser.
5. Write the current date on the lter in the space
provided. Attach the lter cartridge by rmly inserting
it onto the lter head and twisting it clockwise until it is
completely seated. The label must be facing outward
to be correctly installed.
Note: When a filter requires replacement, a red indicator
light illuminates on the bottle filler. If the new filter
is installed and red indicator light is still ON the
filter has been installed incorrectly. The filter can
only be installed in one direction (label facing
outward). If the red indicator light is ON, the filter is
installed backwards.
Note: Depending on chosen configuration installation,
either proceed to section 4.6 for optional waste
drain and catch basin installation or section 5 for
startup.