5. Connect the 1/4" insulated water line to either a
remote chiller (if used) or the 1/4" water line on
the bottle ller. Use a union connection tting to
connect the water line to the bottle ller. The type of
1/4" tubing, copper or plastic, should meet all local
regulations and building codes. This line should be
insulated to prevent condensation.
NOTICE
Do not disconnect the 1/4"
tubing from the water valve at
the top of the water dispenser. This connection has
been factory tested to be leak-free and could result in
water leaking into the unit if this connection is
changed.
Note: Do not place the remote filter more than 15 feet
from the water dispenser.
6. Connect the extension cable (18 foot NFC wire) from
the NFC card circuit board to the wire harness on the
water dispenser circuit board.
7. Mark the current date on the water lter label.
8. Place the lter into lter head with the label facing
outward.
9. Firmly press the lter into the lter head and turn it
clockwise.
Note: When a filter requires replacement, a red indicator
light illuminates on the bottle filler. If the new filter
is installed and red indicator light is still ON the
filter has been installed incorrectly. The filter can
only be installed in one direction (label facing
outward). If the red indicator light is ON, the filter is
installed backwards.
4.5 Installing Remote Water Chiller (optional)
A remote water chiller can be installed in connection with
the water dispenser to supply chilled water. The chiller
must be installed within 15 feet of the water dispenser, in
an accessible location. Install the chiller with adequate
ventilation space, as outlined in the water chiller manual.
The standard installation of the in-wall water dispenser
supplies ltered water at the ambient temperature of the
water supply that comes into the unit. This temperature
can vary greatly depending on the location of the
incoming water line.
Follow the installation instructions that come with the
water chiller. The lter unit must also be installed prior
to the chiller, and the water line from the chiller to the
water dispenser cannot be more than 15 feet long. When
the lter is located in a remote location, mount the lter
vertically on a wall or other supporting structure near the
chiller.
NOTICE
The lter must be installed
before the chiller. The lter will
have water stored within it, so if the lter is after the
chiller, the unit will dispense ambient water for 1-2
cycles before receiving chilled water.
Water
Filter
Water
Chiller
(Optional)
Water
Dispenser
Note: The remote chiller can take from 24 to 48 hours to
provide completely chilled water. Water lines must