Instructions / Assembly
Elkay Manufacturing Company (630) 574-8484
1000005449 (Rev. E - 04/23)
Page 16
NOTICE
For the following steps, it is
recommended to use a heat gun
when manipulating the exible drain hose. It is
benecial to conservatively soften the material before
trying to make connections.
6. Attach one end of the 3/4 inch exible drain hose to
the 3/4 inch barbed drain adapter connection using the
supplied hose clamp. The supplied exible drain is 13
inches long. If a longer drain hose is required, it must
be installer-supplied.
7. Place the drain basin back into the water dispenser
and reinstall the two screws.
8. Route the drain hose through the lter box (if installed)
and attach the other end to the p-trap drain adapter
using a hose clamp. The drain adapter is designed to
be glued into a 1-1/4 inch PVC pipe.
Shown with optional
x.
9. First, write the current date on the lter in the space
provided. Attach the lter cartridge to the lter head by
inserting rmly into the lter head, turning clockwise to
install so the label is facing downward.
10. Connect the drain adapter into the waste drain pipe.
If the p-trap is located inside a sealed walled, it must
have permanently-glued joints. If the p-trap is in an
accessible location, a standard non-glued p-trap is
acceptable.
Note: Whichever installation method is used: it
must meet local standards and building codes.
11. Install the metal grate cover. Do not install the drip
tray since the unit is plumbed into the local waste
line.