Instructions / Assembly

Elkay Manufacturing Company (630) 574-8484
1000005449 (Rev. E - 04/23)
Page 16
NOTICE
For the following steps, it is
recommended to use a heat gun
when manipulating the exible drain hose. It is
benecial to conservatively soften the material before
trying to make connections.
6. Attach one end of the 3/4 inch exible drain hose to
the 3/4 inch barbed drain adapter connection using the
supplied hose clamp. The supplied exible drain is 13
inches long. If a longer drain hose is required, it must
be installer-supplied.
7. Place the drain basin back into the water dispenser
and reinstall the two screws.
8. Route the drain hose through the lter box (if installed)
and attach the other end to the p-trap drain adapter
using a hose clamp. The drain adapter is designed to
be glued into a 1-1/4 inch PVC pipe.
Shown with optional
x.
9. First, write the current date on the lter in the space
provided. Attach the lter cartridge to the lter head by
inserting rmly into the lter head, turning clockwise to
install so the label is facing downward.
10. Connect the drain adapter into the waste drain pipe.
If the p-trap is located inside a sealed walled, it must
have permanently-glued joints. If the p-trap is in an
accessible location, a standard non-glued p-trap is
acceptable.
Note: Whichever installation method is used: it
must meet local standards and building codes.
11. Install the metal grate cover. Do not install the drip
tray since the unit is plumbed into the local waste
line.