3. Installation Preparation
For correct and safe installation, please read these
instructions completely.
All Installation work must be performed by an
authorized service personnel.
Disconnect electrical supply serving the
Installation area to reduce risk of electrocution.
Unit not suitable for installations where water jets
could be used.
WARNING
Shut off water supply serving the Installation area
to reduce risk of water damage.
Ensure proper ventilation by maintaining
clearance from cabinet louvers to wall on each
side of Cooler as specied in Rough-In.
Never wire compressor directly to electrical
supply.
Thoroughly ush all water lines and ttings of all
foreign matter before connecting to Cooler.
Warranty is void if Installation is not made
in accordance with current Manufacturing
instructions.
CAUTION
Hose-sets are not to be used for connecting to
water mains.
If inlet pressure is above 105 psig (0.72 MPa),
a pressure regulator must be installed in water
supply line. Any damage caused by reason of
connecting this product to water supply line
pressure outside it’s rated pressure, is not
covered by warranty.
Tools/Items required but not provided.
- Water Shut-off Valve with 3/8” (9.5mm)
compression outlet.
- Waste Trap (non-metallic)
- Safety Glasses
- Protective Gloves
- Hex drives
- Fasteners for wall type
NOTICE
The installation of this product
requires electrical and plumbing
connections that use specic skills and knowledge. If
you are unsure or not qualied to make these
connections, consult a qualied plumber, electrician,
or installer for this installation. Professional
installation is recommended.
1. This water dispenser is designed for indoor use only
and should not be installed outdoors or in a humid
environment. This water dispenser should not be
installed on exterior walls.
2. Location planning for remote lter and optional chiller
is crucial based on chosen conguration. The location
of the water dispenser must be within 15 feet of
the remote water lter and chiller (chiller optional).
Both must be in an accessible location. For chiller
installation, ensure adequate ventilation space as
outlined in chiller manual. It also must be located after
the lter for proper ltration and cooling (see gure
below).
Water
Filter
Water
Chiller
(Optional)
Water
Dispenser
NOTICE
A water supply pressure below
40 psi will result in decreased
water ow through the unit and damage to the
product. A pressure above 105 psi will also cause
damage to the product.
3. Make sure the water supply pressure to the product
is between 40 and 105 psi. The water dispenser with
lter requires 40 psi minimum water pressure. The
optimum water pressure is 60 psi. The noise level is
lower than 70 dB.
4. Use care when opening and removing the packaging
to prevent damage to the product.
a. Inspect the product for any shipping damage and
report it immediately to the location of purchase.
Installation of a damaged product will void the
warranty.
b. Conrm that all parts have been included for the
proper installation of this product. Contact the
location of purchase if damaged parts are found.
NOTICE
Make sure no electrical wiring,
potable water inlet pipes, or
drain water outlet pipes will be damaged during
installation of the product.
5. Shut off the water supply source and disconnect
power to the electrical circuit being used to operate
the product before starting the installation.