Specification Sheet

Elkay Manufacturing Company
www.elkay.com
2222 Camden Court
Oak Brook, IL 60523
Printed in U.S.A.
©1999 Elkay Mfg. Co.
(Rev. 5/99) 8-1F
SPECIFICATIONS
Design 2000
®
Air Cooled Refrigerated Water Cooler
with WaterSentry
®
VII Filter System
Floor Model LFAE-8
*
Patent #4,481,971
CONSTRUCTION
Fountain Top:
One piece stainless steel top, polished to a uniform Elkay
bright luster finish. Exclusive Cascade basin, tested most splash resistant,
features multi-level deck design with a built-in vandal-resistant strainer.
Exclusive Flexi-Guard
®
Safety Bubbler*:
Innovative design utilizes a
pliable elastomer to prevent accidental mouth injuries. Flexes on impact,
then returns to original position. Strong. Abrasion-resistant. Anti-sweat.
Meets UL requirements and all sanitary codes.
Removable Panel:
Removable front panel offers easy accessibility to
interior.
Color Selection:
Gray Beige vinyl furnished as standard. Stainless steel
is also available at extra cost.
Cabinet:
Cabinet design allows for flush to wall mounting, or free standing.
5 YEAR LIMITED WARRANTY
on the refrigeration system of the unit.
Electrical components and water system are warranted for 12 months from
date of installation. Sample Certificate available on request.
Elkay Pressure-Type Water Coolers are designed to operate on 20 psi to
105 psi supply line pressure. If inlet pressure is above 105 psi, a pressure
regulator must be installed in the supply line. Any damage caused by rea-
son of connecting this product to supply line pressures lower than 20 psi or
higher than 105 psi is not covered by the warranty.
Note:
In keeping with our policy of continuing product improvement, Elkay
reserves the right to change materials, design and specifications without
notice.
Elkay Electric Air Cooled Water Coolers are listed by Underwriters
Laboratories, approved by C.S.A., rated in accordance with A.R.I. Standard
1010 and meet all known federal and state plumbing codes.
GENERAL
Self-contained, electric refrigerated, floor model water cooler. Capacity
of 50
O
F drinking water, based upon 80
O
F inlet water and 90
O
F ambient.
Non-pressurized tank system is standard. Non-pressurized water tank is
located after bubbler valve, so that tank is subject to line pressure only
when valve button is pressed.
NO LEAD DESIGN
THIS WATER COOLER COMPLIES WITH THE LEAD-FREE
DEFINITION IN THE SAFE DRINKING WATER ACT OF 1986 AND
LEAD CONTAMINATION CONTROL ACT OF 1988.
Elkay Design 2000 Water Coolers are manufactured with a waterway
system utilizing copper components and completely lead-free material.
These waterways have no lead because all lead materials, such as leaded
brass, have been removed. All joints are brazed using silver solder only. No
lead solder is permitted.
This water cooler is classified by Underwriters Laboratories Inc.
in accordance with ANSI/NSF61, Section 9-1997b.
WATERSENTRY
®
Vll FILTER SYSTEM
Elkay Design 2000 Water Coolers are equipped with the WaterSentry VII
Filter System, which is tested and certified by NSF International.
The WaterSentry VII Filter System reduces cysts such as cryptosporidium
and giardia by 99.99%. Tested to ANSI/NSF Standard 53 yields a reduction
of soluble and insoluble lead content to less than 0.015mg/l. This translates
to lead reduction levels of 93% to 99%. Class 1 particulate reduction as
tested per ANSI/NSF 42. Removes over 97.5% of free available chlorine
which provides Class 1 performance as tested to ANSI/NSF 42. Provides
taste and odor improvement.
CAPACITIES CHART
**Based on 80
O
F inlet water temperature.
† Glass filler available at extra cost. Requires factory preparation to receive glass filler.
Rated watts shown are based on operational (run) time, in accordance with ARI
Standard 1010 conditions. Specific applications will determine the actual watts
consumed per hour. Watts consumed will be based on number of people served
per hour (usage), ambient temperatures, and inlet water temperature.
Foot pedal available. Factory installed only.
COOLING SYSTEM
Motor Compressor:
Hermetically sealed, reciprocating type, 115V, 60
Hertz single phase. Sealed-in lifetime oil supply. Equipped with electric
cord and three prong molded rubber plug.
Condenser:
Fan cooled, copper tube with aluminum fins. Fan motor is
permanently lubricated.
Cooling Unit:
Combination tube-tank type. Tube portion is continuous coil
of copper tubing. Fully insulated with EPS foam which meets Underwriters
Laboratories requirements for self extinguishing material.
Refrigerant Control:
Refrigerant HFC-134a is controlled by accurately
calibrated capillary tube for positively trouble free performance.
Temperature Control:
Enclosed adjustable thermostat is factory preset.
Requires no adjustment other than for altitude requirements.
LFAE-8 5.3 10.2 9.6 8.9 8.2 420 5.5 YES 83
Model
Number
Base
Rate
Rated
Watts
Full
Load
Amps
Ship.
Wt.
Lbs.
Glass†
Filler
Option
**GPH of 50° F
Drinking Water
Room Temperature ° F
70°F 80°F 90°F 100°F
Model LFAE-8

Summary of content (2 pages)