4400FR_FTN LK4400FR_FTN Owners Manual 4400 Freeze Resistant Tubular Fountain with 97243C Single Valve Control Assembly INSTALLER 4400FR Fountains are among the easiest to install Fountains on the market today. To assure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES.
4400FR_FTN LK4400FR_FTN INSTALLATION INSTRUCTIONS IMPORTANT THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED.
4400FR_FTN LK4400FR_FTN SITE PREPARATION DETAIL FOR THE 4400FR FTN. WHEN USING 97243C SINGLE VALVE CONTROL ASSY. E G (6)1/2" (13mm) DIA. HOLES EQUALLY SPACED ON A 12" (305mm) BOLT CENTER PVC COLUMN CENTERED BETWEEN MOUNTING BOLT HOLES O 14" 356mm F FIG. 1 O 10" 254mm SITE PREPARATION DETAIL FIG. 2 CONCRETE SLAB F H FROST LINE DEPTH DEPENDANT ON GEOGRAPHIC LOCATION AND LOCAL REQUIREMENTS 36" MIN 67" MAX 4" 102mm E G D C BACK FILL ( DIRT ) B FROST LINE FILL LINE 12" 305mm MIN.
400FR_FTN LK4400FR_FTN TROUBLE SHOOTING AND MAINTENANCE Insufficient Bubbler Flow: Check that the shut-off valve is wide open. Verify minimum 20 PSI supply pressure. Clean inlet strainer screen located in the valve body. Clean rubber orifice in flow control located below frost line in bushing between barb fitting and valve. No Flow: Check for leaks in the air tubing going from the push button to the valve. Make sure the air tubing compression nut is hand tight. Disconnect air tube from push button.
4400FR_FTN LK4400FR_FTN 25 29 8 11 5 23 8 8 4 16 10 20 Single Valve Assy. (Item *28) The following items are included with the 4400FR Fountain PARTS LIST ITEM NO. PART NO.
4400FR_FTN LK4400FR_FTN Owners Manual 4400 Freeze Resistant Tubular Fountain with SanitaryFR1 Valve INSTALLATION INSTRUCTIONS IMPORTANT! INSTALLER PLEASE NOTE Tubing must be cut to the right length. Do not coil any excess tubing or it will cause valve to malfunction. General Installation Tips 1. Prepare trench for water supply and waste drain lines. The hole should be deep enough to accommodate the PVC column. Additional porous fill and drain pipe may be required due to local ground conditions.
4400FR_FTN LK4400FR_FTN SUGGESTED SITE PREPARATION DETAIL FOR THE 4400FR FTN. WHEN USING THE SANITARYFR1 VALVE 1-1/2" DRAIN TUBE (SUPPLIED BY INSTALLER) 4" PVC 1/4 BEND (SUPPLIED BY INSTALLER) 4" PVC PIPE (SUPPLIED BY INSTALLER) CONCRETE SLAB CLEANOUT PLUG FOR ACCESS (SUPPLIED BY INSTALLER) 4" 102mm MIN. 8 INCH INSIDE DIA. PVC PIPE, TRIM TO DESIRED LENGTH (SUPPLIED BY INSTALLER) 36" MIN. (914mm) 60"MAX. (1524mm) FROST LINE PVC 8" x 8" x 4" COMBINATION "Y" & 1/8 BEND REDUCING ASSY.
4400FR_FTN LK4400FR_FTN SUGGESTED SITE PREPARATION DETAIL FOR THE 4400FR FTN. WHEN USING THE SANITARYFR1 VALVE (6) 1/2" (13mm) DIA. HOLES EQUALLY SPACED ON A 12" ( 305mm ) BOLT CENTER 1-1/4 DRAIN TUBE SUPPLIED WITH FTN. AIR GAP ASSY. SUPPLIED WITH VALVE 14" O 356mm 10" O 254mm 2 13/16" 72mm A SEE DETAIL A 30" 762mm 42 3/16" 1072mm 40 5/16" 1025mm 1-1/2 DRAIN TUBE SUPPLIED BY INSTALLER CONCRETE SLAB 8" 203mm Detail A 4" 102mm FIG.
4400FR_FTN LK4400FR_FTN E G C H A FOUNTAIN CONNECTIONS PLUMBING CONDUIT (BY INSTALLER) TO VALVE FIG. 3 INSTRUCTIONS FOR CONNECTING TUBES FROM VALVE TO FOUNTAIN Step 1 - Insert the 1/8” O.D. tube (Label A) into the connector (provided with fountain). Insert the 1/8” O.D. tube coming from the fountain push button actuator into the connector. Trim any excess length. Step 2 - Secure the 1/8” O.D. tube (Label C) to the waste line assembly. This line is a vent line and should be open to the air.
4400FR_FTN LK4400FR_FTN Stream Height Adjustment 5 4 3, 11 12 See Detail B 5 14 2 10 15 FIG. 5 FIG. 4 6 13 6 15 5 13 Detail B 97731C (Rev.
4400FR_FTN LK4400FR_FTN The Following Items are included with the SanitaryFR1 Valve PARTS LIST ITEM NO. PART NO.
4400FR_FTN LK4400FR_FTN TROUBLE SHOOTING AND MAINTENANCE Insufficient Bubbler Flow: Check that the shut-off valve is wide open. Verify minimum 20 PSI supply pressure. Clean inlet strainer screen located in the valve body. Clean rubber orifice in flow control located below frost line in bushing between barb fitting and valve. No Flow: Check for leaks in the air tubing going from the push button to the valve. Make sure the air tubing compression nut is hand tight. Disconnect air tube from push button.
4400FR_FTN LK4400FR_FTN FIG. 9 19 27 19 23 19 20 31 Bubbler Detail 21 19 18 25 32 The Following Items are included with the 4400FR Fountain PARTS LIST ITEM NO. PART NO.