Installation Sheet

PAGE 4
98877C (Rev. B - 12/15)
4405BFFR_FTN LK4405BFFR_FTN
27"
686mm
ADA
REQUIREMENT
37"
940mm
14 9/16"
371mm
57"
1448mm
10"
254mm
O
3"
76mm
12"
305mm
MAX. WALL
THICKNESS
2 5/8"
67mm
3 5/8"
92mm
8"
203mm
20 3/16"
513mm
19 1/8"
486mm
FINISHED FLOOR
23 11/16"
602mm
FIG. 2
4405BFFR BOTTLE FILLING FREEZE RESISTANT FOUNTAIN
ROUGH-IN DRAWINGS
1. Wall should already be framed for the fountain using dimensions shown in Fig. 1. Shown dimensions pertain to installation location.
These dimensions are required for compliance with ANSI Standard A117.1. and ADA (Framing shown for reference only).
2. Remove bottom cover from fountain and save screws.
3. Install the fountain using 3/8" minimum fasteners and washers (not provided). Tighten securely.
4. Prior to installing bottle ller to the fountain, insert the drain tube (item #4) into the arm tunnel and adjust drain to lean to the left side when facing button.
5. Install bottle ller to fountain being sure drain tube is above mounting plate of ller. Install mounting hardware to secure ller to fountian.
6. Attach drain tube to fountain and cut to required length using the freeze resistant box as a guide.
7. Install freeze-resistant box - see box instructions.