4410FR_FTN LK4410FR_FTN Owners Manual 4410 Freeze Resistant Tubular Fountain with 97243C Single Valve Control Assembly INSTALLER 4410FR Fountains are among the easiest to install Fountains on the market today. To assure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES.
4410FR_FTN LK4410FR_FTN INSTALLATION INSTRUCTIONS IMPORTANT THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED.
4410FR_FTN LK4410FR_FTN SITE PREPARATION DETAIL FOR THE 4410FR FTN. WHEN USING 97243C SINGLE VALVE CONTROL ASSY. F H PVC COLUMN CENTERED BETWEEN MOUNTING BOLT HOLES (6) 1/2" (13mm) DIA. HOLES EQUALLY SPACED ON A 12" (305mm) BOLT CENTER G FIG. 1 O 14" 356mm SITE PREPARATION DETAIL FIG.
410FR_FTN LK4410FR_FTN TROUBLE SHOOTING AND MAINTENANCE Insufficient Bubbler Flow: Check that the shut-off valve is wide open. Verify minimum 20 PSI supply pressure. Clean inlet strainer screen located in the valve body. Clean rubber orifice in flow control located below frost line in bushing between barb fitting and valve. No Flow: Check for leaks in the air tubing going from the push button to the valve. Make sure the air tubing compression nut is hand tight. Disconnect air tube from push button.
4410FR_FTN 29 LK4410FR_FTN 30 8 31 11 12 13 24 8 4 Single Valve Assy. (Item 28) 9 25 8 9 6 7 14 9 The following items are included with the 4410FR Fountain 1 15 PARTS LIST ITEM NO. PART NO.
4410FR_FTN LK4410FR_FTN Owners Manual 4410 Freeze Resistant Tubular Fountain with SanitaryFR1 Valve IMPORTANT! INSTALLER PLEASE NOTE Tubing must be cut to the right length. Do not coil any excess tubing or it will cause valve to malfunction. General Installation Tips 1. Prepare trench for water supply and waste drain lines. The hole should be deep enough to accommodate the PVC column. Additional porous fill and drain pipe may be required due to local ground conditions.
4410FR_FTN LK4410FR_FTN SUGGESTED SITE PREPARATION DETAIL FOR THE 4410FR FTN. WHEN USING THE SANITARYFR1 VALVE 1-1/2" DRAIN TUBE (SUPPLIED BY INSTALLER) 4" PVC 1/4 BEND (SUPPLIED BY INSTALLER) 4" PVC PIPE (SUPPLIED BY INSTALLER) CONCRETE SLAB CLEANOUT PLUG FOR ACCESS (SUPPLIED BY INSTALLER) 4" 102mm MIN. 8 INCH INSIDE DIA. PVC PIPE, TRIM TO DESIRED LENGTH (SUPPLIED BY INSTALLER) 36" MIN. (914mm) 60"MAX. (1524mm) FROST LINE PVC 8" x 8" x 4" COMBINATION "Y" & 1/8 BEND REDUCING ASSY.
4410FR_FTN LK4410FR_FTN SUGGESTED SITE PREPARATION DETAIL FOR THE 4410FR FTN. WHEN USING THE SANITARYFR1 VALVE 1-1/4 DRAIN TUBE SUPPLIED WITH FTN. ( 6 ) 1/2" ( 13mm ) DIA. HOLES EQUALLY SPACED ON A 12" ( 305mm ) BOLT CENTER AIR GAP ASSY. SUPPLIED WITH VALVE 14" O 356mm 29" 737mm 10" O 254mm 2 7/8" 73mm A SEE DETAIL A 19" 483mm B 27 1/4" 692mm 35 3/16" 894mm 1-1/2 DRAIN TUBE SUPPLIED BY INSTALLER 33 5/16" 847mm 27" 686mm Detail A 8" 203mm 4" 102mm FIG.
4410FR_FTN LK4410FR_FTN E G C H A FOUNTAIN CONNECTIONS PLUMBING CONDUIT (BY INSTALLER) TO VALVE FIG. 3 INSTRUCTIONS FOR CONNECTING TUBES FROM VALVE TO FOUNTAIN Step 1 - Insert the 1/8” O.D. tube (Label A) into the connector (provided with fountain). Insert the 1/8” O.D. tube coming from the fountain push button actuator into the connector. Trim any excess length. Step 2 - Secure the 1/8” O.D. tube (Label C) to the waste line assembly. This line is a vent line and should be open to the air.
4410FR_FTN LK4410FR_FTN Stream Height Adjustment 4 5 3, 11 12 See Detail B 5 14 2 10 15 FIG. 5 FIG. 4 6 13 6 15 5 13 Detail B 97733C (Rev.
4410FR_FTN LK4410FR_FTN The Following Items are included with the SanitaryFR1 Valve PARTS LIST ITEM NO. PART NO.
4410FR_FTN LK4410FR_FTN TROUBLE SHOOTING AND MAINTENANCE Trouble Shooting Insufficient Bubbler Flow: Check that the shut-off valve is wide open. Verify minimum 20 PSI supply pressure. Clean inlet strainer screen located in the valve body. Clean rubber orifice in flow control located below frost line in bushing between barb fitting and valve. No Flow: Check for leaks in the air tubing going from the push button to the valve. Make sure the air tubing compression nut is hand tight.
4410FR_FTN LK4410FR_FTN 30 29 19 27 23 19 19 20 19 BASIN 26 22 26 32 24 26 36 18 Bubbler Detail FIG. 9 33 The Following Items are included with the 4410FR Fountain 35 PARTS LIST ITEM NO. PART NO.