4420FR_FTN LK4420FR_FTN Owners Manual 4420 Freeze Resistant Tubular Fountain with 97482C Dual Valve Control Assembly INSTALLER 4420FR Fountains are among the easiest to install Fountains on the market today. To assure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES.
4420FR_FTN LK4420FR_FTN INSTALLATION INSTRUCTIONS IMPORTANT THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED.
4420FR_FTN LK4420FR_FTN SITE PREPARATION DETAIL FOR THE 4420FR FTN. WHEN USING 97482C DUAL VALVE CONTROL ASSY. F H PVC COLUMN CENTERED BETWEEN MOUNTING BOLT HOLES (6) 1/2" (13mm) DIA. HOLES EQUALLY SPACED ON A 12" (305mm) BOLT CENTER G FIG. 1 O 14" 356mm FIG. 2 29" 737mm CONCRETE SLAB SITE PREPARATION DETAIL FIG.
420FR_FTN LK4420FR_FTN TROUBLE SHOOTING AND MAINTENANCE TROUBLE SHOOTING Insufficient Bubbler Flow: Check that the shut-off valve is wide open. Verify minimum 20 PSI supply pressure. Clean inlet strainer screen located in the valve body. Clean rubber orifice in flow control located below frost line in bushing between barb fitting and valve. No Flow: Check for leaks in the air tubing going from the push button to the valve. Make sure the air tubing compression nut is hand tight.
4420FR_FTN LK4420FR_FTN 12 25 23 33 4 9 1 19 2 27 Dual Valve Assy. (Item 32) 8 5 5 12 10 6 PART NO.
4420FR_FTN LK4420FR_FTN Owners Manual 4420 Freeze Resistant Tubular Fountain with SanitaryFR2 Valve IMPORTANT! INSTALLER PLEASE NOTE Tubing must be cut to the right length. Do not coil any excess tubing or it will cause valve to malfunction. General Installation Tips 1. Prepare trench for water supply and waste drain lines. The hole should be deep enough to accommodate the PVC column. Additional porous fill and drain pipe may be required due to local ground conditions.
4420FR_FTN LK4420FR_FTN SUGGESTED SITE PREPARATION DETAIL FOR THE 4420FR FTN. WHEN USING THE SANITARYFR2 VALVE 1-1/2" DRAIN TUBE (SUPPLIED BY INSTALLER) 4" PVC 1/4 BEND (SUPPLIED BY INSTALLER) 4" PVC PIPE (SUPPLIED BY INSTALLER) CONCRETE SLAB CLEANOUT PLUG FOR ACCESS (SUPPLIED BY INSTALLER) 4" 102mm MIN. 8 INCH INSIDE DIA. PVC PIPE, TRIM TO DESIRED LENGTH (SUPPLIED BY INSTALLER) 36" MIN. (914mm) 60"MAX. (1524mm) FROST LINE PVC 8" x 8" x 4" COMBINATION "Y" & 1/8 BEND REDUCING ASSY.
4420FR_FTN LK4420FR_FTN SUGGESTED SITE PREPARATION DETAIL FOR THE 4420FR FTN. WHEN USING THE SANITARYFR2 VALVE 1-1/2 DRAIN TUBE SUPPLIED WITH FTN. ( 6 ) 1/2" ( 13mm ) DIA. HOLES EQUALLY SPACED ON A 12" ( 305mm ) BOLT CENTER AIR GAP ASSY. SUPPLIED WITH VALVE 14" O 356mm 29" 737mm 10" O 254mm 2 7/8" 73mm A SEE DETAIL A 27 1/4" 692mm 19" 483mm B 35 3/16" 894mm 1-1/2 DRAIN TUBE SUPPLIED BY INSTALLER 33 5/16" 847mm 27" 686mm Detail A 8" 203mm 4" 102mm FIG.
4420FR_FTN LK4420FR_FTN E G C H A FOUNTAIN CONNECTIONS PLUMBING CONDUIT (BY INSTALLER) TO VALVE FIG. 3 INSTRUCTIONS FOR CONNECTING TUBES FROM VALVE TO FOUNTAIN(S) Step 1 - Insert the 1/8” O.D. tube(s) (Labeled A & B) into the connector(s) (provided with fountain). Insert the 1/8” O.D. tube(s) coming from the fountain(s) push button actuator(s) into the connector(s). Trim any excess length. Step 2 - Secure the 1/8” O.D. tube(s) (Labeled C & D) to the waste line assembly.
4420FR_FTN LK4420FR_FTN Stream Height Adjustment 6 7 7 5, 13 14 3 2 4 7 16 12 17 FIG. 5 FIG. 4 SEE DETAIL B 8 7 8 8 15 8 15 17 DETAIL B FIG. 6 97734C (Rev.
4420FR_FTN LK4420FR_FTN The Following Items are included with the SanitaryFR2 Valve PARTS LIST ITEM NO. PART NO.
4420FR_FTN LK4420FR_FTN TROUBLE SHOOTING AND MAINTENANCE Trouble Shooting Insufficient Bubbler Flow: Check that the shut-off valve is wide open. Verify minimum 20 PSI supply pressure. Clean inlet strainer screen located in the valve body. Clean rubber orifice in flow control located below frost line in bushing between barb fitting and valve. No Flow: Check for leaks in the air tubing going from the push button to the valve. Make sure the air tubing compression nut is hand tight.
4420FR_FTN LK4420FR_FTN 29 25 22 21 20 27 BASIN 39 38 23 Vandal-Resistant Bubbler Detail FIG. 10 24 26 34 The Following Items are included with the 4420FR Fountain 21 29 25 28 28 21 21 28 22 PARTS LIST ITEM NO. PART NO.