Installation Sheet

PAGE 9
4400BFFR_FTN_A LK4400BFFR_FTN_A
1000003953 (Rev. B - 03/20)
1.Thisfountainistobemountedonasmooth,at,nishedsurfacewithadequatesupportstructure.NOTE:Mountingstructure
must be capable of supporting 300 lb. load on fountain.
2. Refer to rough-in for plumbing.
3.Installshut-o󰀨valveonwatersupply.(Valvenotfurnished)
4. Locate and install fountain using 3/8" minimum fasteners. (Fasteners not furnished)
5. Prior to installing the Bottle Filler to the fountain, insert drain tube (Item # 20) by positioning the short end of drain pipe
throughthemountingplateofbottleller.Next,placetheaestheticcollar(item#30)ontothecentermountingpositionof
the fountain ensuring the vertical edge of the collar is upright and the curved edge sits below the mounting surface. Mount
bottlellertofountainwithcollarcenteredbetweenthetwopieces.Securewithsuppliedhardware.
6.Connectwatersupplyandfountaindrain.ConnectBottleFillerwaterlinetofreezevalvesasspeciedinabovesections.
water connection and drain must comply with local codes.
7. Turn on water supply and check all connections for leaks.
CAUTION:Thisfountainisratedforinletwaterpressureof20-105PSI.Apressurereducingregulatorshouldbeusedifthe
inlet water supply exceeds 105 PSI. Any damage caused by reason of connecting this product to supply line
pressures lower than 20 PSI or higher than 105 PSI is not covered by warranty.
INSTALLATION INSTRUCTIONS
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE
BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN
ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE
WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN
FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE
FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.