Specification Sheet

Wall Mount Water Cooler with Water Sentry
®
VII
Filter System – Barrier-Free Access
(Adult or Child) – NSF/ANSI 61 Compliant
Models LMABF8 and LMABFD
®
SPECIFICATIONS
GENERAL
Self-contained, wall hung electric refrigerated, water cooler.
Capacity 8.0 GPH of 50°F drinking water, based upon 80°F
inlet water and 90°F ambient.
All models have a hooded stream projector with self closing
push bars on front and both right and left sides. Patented*
valve with built-in flow regulator provide constant stream from
20 to 105 psi (138 to 724 KPa) water pressure. Bubbler orifice
fully protected to meet all sanitary codes.
Non-pressurized cooling tank is standard. Non-pressurized
water tank is located after bubbler valve, so that the tank is
subject to line pressure only when push bar is pressed.
ADA COMPLIANT
These Water Coolers comply with the requirements of A.D.A.
(Americans with Disabilities Act) when properly installed. Also
meets the guidelines for childrens environments providing
the floor to orifice height is 30" or less and proper clear floor
space is provided for parallel approach. (Based on
Architectural and Transportation Barriers Compliance Board
final ruling.) Check Local and State Codes.
NO LEAD DESIGN
These Water Coolers are certified to be lead-free as defined
by the Safe Drinking Water Act. Elkay Water Coolers are man-
ufactured with a waterway system utilizing copper compo-
nents and completely lead-free materials. These waterways
have no lead because all lead materials, such as leaded
brass, have been removed. All joints are brazed using silver
solder only. No lead solder is permitted. A strainer with an
easily cleanable screen is provided to allow trapping and con-
venient removal of waterborne particulate of 140 microns and
larger prior to their entry into the water cooler.
These water coolers are certified to
NSF/ANSI 61.
WATERSENTRY
®
VII FILTER SYSTEM
Elkay Water Coolers are equipped with the WaterSentry VII Filter
System, which is tested and certified by NSF International. The
WaterSentry VII Filter System reduces cysts such as cryp-
tosporidium and giardia by 99.99%. Tested to NSF/ANSI
Standard 53 yields a reduction of soluble and insoluble lead con-
tent to less than 0.015mg/l. This translates to lead reduction
levels of 93% to 99%. Class 1 particulate reduction as tested per
NSF/ANSI 42. Removes over 97.5% of free available chlorine
which provides Class 1 performance as tested to NSF/ANSI 42.
Provides taste and odor improvement.
COOLING SYSTEM
Motor Compressor: Hermetically sealed, reciprocating type,
120 Volt/60 Hz, single phase. Sealed-in lifetime oil supply.
Equipped with electric cord and three prong molded rubber
plug.
Condenser: Fan cooled, copper tube with aluminum fins. Fan
motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Tube portion is
continuous coil of copper tubing. Fully insulated with EPS
foam which meets Underwriters Laboratories Inc. require-
ments for self extinguishing material.
Refrigerant Control: Refrigerant HFC-134a is controlled by
accurately calibrated capillary tube for positively trouble-free
operation.
Temperature Control: Enclosed adjustable thermostat is
factory preset. Requires no adjustment other than for altitude
requirements. Easily accessible.
CONSTRUCTION
Frame: Galvanized structural steel chassis supports fountain
top and cabinet panels.
Fountain Top: Series 300 one piece stainless steel top,
polished to a uniform Elkay bright luster finish. Basin has
embossed bubbler pad.
Exclusive Flexi-Guard
®
Safety Bubbler*: Innovative design
utilizes a pliable polyester elastomer to prevent accidental
mouth injuries. Flex on impact, then returns to original posi-
tion. Strong. Abrasion-resistant. Anti-sweat. Bubbler meets
UL requirements and all sanitary codes and is keyed in loca-
tion to prevent rotation.
Cabinet: Cabinet design allows for flush to wall mounting. No
recess space is required. Includes bottom cover plate
fastened with standard screws.
Color Selection: Light Gray Granite furnished as standard.
Stainless steel available at extra cost.
5 YEAR LIMITED WARRANTY on the refrigeration system of
the unit. Electrical components and water system are war-
ranted for 12 months from date of installation. Sample
Certificate available on request.
Elkay Pressure-Type Water Coolers are designed to operate
on 20 psi (138 KPa) to 105 psi (724 KPa) supply line pressure.
If inlet pressure is above 105 psi (724 KPa), a pressure
regulator must be installed in the supply line. Any damage
caused by reason of connecting this product to supply line
pressures lower than 20 psi (138 KPa) or higher than 105 psi
(724 KPa) is not covered by the warranty.
STANDARDS
Model LMABF8
Elkay
2222 Camden Court
Oak Brook, IL 60523
Printed in U.S.A.
©2006 Elkay
(Rev. 10/06) 12-52A
elkayusa.com
In keeping with our policy of continuing product improvement, Elkay reserves the right to change
product specifications without notice.
This specification describes an Elkay product with design, quality and functional benefits to the
user. When making a comparison of other producers’ offerings, be certain these features are not
overlooked.
* Patent #4,481,971
Elkay Electric Air Cooled Water Coolers are listed
by Underwriters Laboratories Inc. and comply with
both Canadian and U.S. Requirements.
CAPACITIES CHART
**Based on 80°F (27°C) inlet water temperature.
Rated watts shown are based on operational (run) time, in compliance with A.R.I.
Standard 1010 conditions. Specific applications will determine the actual watts
consumed per hour. Watts consumed will be based on number of people
served per hour (usage), ambient temperatures, and inlet water temperature.
**GPH of 50°F
Drinking Water
Ship.
Room Temperature °F
Full Glass Wt.
Model Volt./ Base 70°F 80°F 90°F Rated Load Filler Lbs.
Number Hertz Rate (21°C) (27°C) (32°C) Watts Amps Option (Kg.)
LMABF8
120V/
8.0 9.7 8.8 8.0 370 4.0 No 67
60Hz
LMABFD ––– No 39

Summary of content (2 pages)