Specification Sheet
12 5/16"
313mm
FINISHED FLOOR
HANGER BRACKET
1 3/8"
35mm
1 3/8"
35mm
5 3/4"
146mm
5 3/4"
146mm
E
F
L
C
27"
686mm
ADA
REQUIREMENT
13 7/8"
352mm
18 3/8"
467mm
21 3/8"
543mm
25"
635mm
31"
787mm
5/16" (8mm) DIA. (5 HOLES)
2 1/2"
64mm
3 1/2"
89mm
4 1/2"
114mm
2 7/16"
63mm
5"
127mm
10"
254mm
11/16"
18mm
2 9/16"
65mm
7 1/4"
185mm
A
D
B
E
6 1/4"
159mm
8"
203mm
1 1/2"
38mm
C
4 9/16"
116mm
6 3/4"
172mm
7"
178mm
7"
178mm
O
7/16"
11mm
MOUNTING HOLES
(6)
15"
381mm
3 3/16"
82mm
52 1/16"
1323mm
17 7/8"
454mm
3 9/16"
90mm
18 1/2"
471mm
18 7/8"
479mm
31 13/16"
808mm
RIM
HEIGHT
33"
838mm
ORIFICE
HEIGHT
2 5/8"
67mm
ACTIVATION
SENSOR
39 1/16"
991mm
EZH2O
®
Bottle Filling Station
With Single Filtered Mechanically-Activated Water Cooler
Models LMABF8WS and LMABFDWS
ROUGH-IN DIMENSIONS
2222 Camden Court
Oak Brook, IL 60523
elkay.com
Printed in U.S.A.
© 2014 Elkay
NOTICE
This water cooler must be connected to the water supply using a dielectric
coupling. The cooler is furnished with a non-metallic strainer which meets this
requirement. The drain trap which is provided by the installer should also be
plastic to completely isolate the cooler from the building plumbing system.
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER
Job Name: ____________________________________
Model: _______________________ Qty. ____________
Contact: ______________________________________
Approval Signature: _____________________________
Notes:
LEGEND:
A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept
3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall.
B = Recommended Waste Outlet location. To accommodate 1-1/4” nominal drain.
Drain stub 2” (51mm) out from wall.
C = 1-1/4” Trap (not furnished).
D = Electrical Supply (3) Wire Recessed Box Duplex Outlet.
E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet
louvers to wall.
F = 7/16” (11mm) Bolt Holes for fastening to wall.
**New Installations Must Use Ground Fault Circuit Interrupter (GFCI).
IMPORTANT!
INSTALLER PLEASE NOTE
This water cooler has been designed and built to provide water to the user which
has not been altered by materials in the cooler waterways. The grounding of
electrical equipment such as telephone, computers, etc., to water lines is a
common procedure. This grounding may be in the building but may also occur
away from the building. This grounding can cause electrical feedback into a
water cooler creating an electrolysis which creates a metallic taste or causes
an increase in the metal content of the water. This condition is avoidable by
installing the cooler using the proper materials as shown below.
Bottle Filler unit will mount on bracket attached to wall by 6 holes (as shown).
Water and electrical will connect through pre-punched hole in basin.