(L)VRCDWS*A, *2A (L)VRC8WS*1A, *2A, *3A INSTALLATION and USE MANUAL Models (L)VRC8WS, (L)VRC8WSJO Factory Prep ezH2O® Bottle Filling Station and Cooler Model LVRC8WS Page 1 98980C (Rev.
(L)VRCDWS*A, *2A (L)VRC8WS*1A, *2A, *3A TOOLS REQUIRED BUT NOT PROVIDED: SAFETY GLASSES GLOVES ELECTRIC DRILL 3/4” WRENCH OR CRESCENT WRENCH UTILITY KNIFE TAPE MEASURE PENCIL CENTER PUNCH 1/2” SOCKET & RATCHET WRENCH 5/32” ALLEN WRENCH IMPORTANT! INSTALLER PLEASE NOTE THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING.
(L)VRCDWS*A, *2A (L)VRC8WS*1A, *2A, *3A Note: Danger! Electric shock hazard. Disconnect power before servicing unit. Pictured is unit only without Bottle Filler Uses HFC-134A refrigerant 10 20 3 7 12 15 6 6 16 See Fig. 8 1 22 17, 18 See Fig. 7 25 See Fig. 9 27 27 See Fig. 7 21 21 24 23 21 21 11 8 19 31 30 9 21 21 27 4, 5 2 4 2 27 Fig. 1 Page 3 98980C (Rev.
98980C (Rev. Q - 12/18) Fig. 2 Page 4 A D B 5" 127mm 1-1/4" 32mm 7" 178mm 2-1/2" 63mm 11/16" 18mm FINISHED FLOOR 10" 254mm 4-1/2" 114mm 2-7/16" 63mm 3-1/2" 89mm 1-1/4" 32mm 7" 178mm 2-9/16" 65mm 7-1/4" 185mm 13-7/8" 352mm F E 4-9/16" 116mm 18-1/2" 470mm 27" 686mm * 8" 203mm 12-5/16" 312mm C 2-5/8" 66mm HANGER BRACKET 18-9/16" 472mm 6-1/4" 159mm 5-1/8" 131mm * ADA REQUIREMENT 6-3/4" 171mm 1-1/2" 38mm LEGEND: A = RECOMMENDED WATER SUPPLY LOCATION 3/8” O.D.
(L)VRCDWS*A, *2A (L)VRC8WS*1A, *2A, *3A MOUNTING SCREWS TOP COVER BOTTLE FILLER MOUNTING BRACKET FOR FASTENING UNIT TO WALL MOUNTING SCREWS DO NOT REMOVE NOTE: TRIM PLATES MUST BE INSTALLED ON THE INSIDE OF THE BOTTLE FILLER SIDE PANEL SLOTS. WATER COOLER Fig. 3 BOTTLE FILLER INSTALLATION (NON-FILTERED MODEL VRC AND FILTERED MODEL LVRC) 1) Remove wall mounting plate from Cooler. Install Wall Mounting Plate as per rough-in diagram (See rough-in on page 4).
(L)VRCDWS*A, *2A (L)VRC8WS*1A, *2A, *3A REMOVAL OF BOTTLE FILLER FOR SERVICING 1) Turn off the water supply to the Water Cooler. Unplug and/or turn off Circuit Breaker to Cooler and Bottle Filler. NOTE: the Lower Front Panel of the cooler(s) may need to be removed. To prevent scratching the basin place a towel or soft cloth over the entire basin when working above it. 2) Loosen but DO NOT remove the two (2) Pinned Torx Head Screws from the sides of the Bottle Filler.
(L)VRCDWS*A, *2A (L)VRC8WS*1A, *2A, *3A 33 PUSH BUTTON MECHANISM 17 17 17 18 26 28 32 29 17 17 29 29 13 17 27 29 Fig. 7 27 22 1 25 1 Basin Fig. 9 VANDAL RESISTANT BUBBLER DETAIL 14 14 14 14 15 Fig. 8 Page 7 98980C (Rev.
(L)VRCDWS*A, *2A (L)VRC8WS*1A, *2A, *3A BF11 - BF12 PROGRAM SETTING THE CONTROL BOARD VERIFY CONTROL BOARD SOFTWARE 1) To verify the software program of the control board the unit will need to be shut down and restarted. The chiller (if present) does not need to be shut down and restarted. 2) The units lower panel must be open to access the power cord and wall outlet. 3) Shut down the unit by unplugging the power cord from the wall outlet or switching off the circuit breaker to the unit.
(L)VRCDWS*A, *2A 27 (L)VRC8WS*1A, *2A, *3A 28 3 2 2 1 WATERSENTRY® PLUS FILTER PARTS LIST ITEM NO. PART NO. 1 2 51300C 51300C_12PK 98926C 3 1000003563 DESCRIPTION Filter Assy-3000 Gallon (Single) Filter Assy-3000 Gallon (12 Pack) Kit-Filter Head Fittings-includes John Guest Fittings Assy-Filter Head & Brkt includes Filter Head/ Mtg Brkt/John Guest Ftgs/Screws WATER FILTER EXPLODED VIEW Fig. 11 Fig.
(L)VRCDWS*A, *2A (L)VRC8WS*1A, *2A, *3A 115V PARTS LIST ITEM PART NO. NO. 1 2 3 *4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 NS NS 97446C 98777C 98775C 36322C 0000000238 75524C 98776C 35839C 98773C 35870C 55996C 27124C 55931C 98684C 45930C 56092C 1000001906 98530C 66703C 98724C 70002C 600985551640 1000001602 1000002062 29014C 22897C 0000001190 28516C 70864C 28525C 28528C 28519C 28522C 22955C 28551C DESCRIPTION BOTTLE FILLER REPLACEMENT PART KITS PART NO.