Specification Sheet

GENERAL
Self-contained, double wall hung electric refrigerated, water
cooler. Vandal-resistant unit for use in high demand locations
where vandalism may occur. Rated for indoor or outdoor use.
Stainless steel construction provides vandal-resistant
enclosure. Optional perforated stainless steel louver screen-
ing prevents objects from being inserted into cooler. Flow
regulator provides constant stream fr
om 20 to 105 psi water
pressure. Heavy dut
y push button control is vandal-resistant.
ADA COMPLIANT
These Water Coolers comply with the requirements of A.D.A.
(Americans with Disabilities Act) when properly installed. Also
meets the guidelines for children’s environments providing
the floor to orifice height is 30" or less and proper clear floor
space is provided for parallel approach. (Based on
Architectu
ral and Transportation Barriers Compliance Board
final ruling.) Check Local and State Codes.
NO LEAD DESIGN
These Water Coolers are certified to be lead-free as defined
by the Safe Drinking Water Act. Elkay Water Coolers are man-
ufactured with a waterway system utilizing copper compo-
nents and completely lead-free materials. All joints are
brazed using silver solder only. A strainer with an easily
cleanable screen is provided to allow trapping and convenient
removal of waterborne particulate of 140 microns and larger
prior to their entry into the water cooler.
COOLING SYSTEM (refrigerated models only)
Hermetically sealed, rec
iprocating type,
120 Volt/60 Hz, single phase or 220-240 Volt/50 Hz or 60 Hz,
two phase. Sealed-in lifetime oil supply. Equipped with elec-
tric cord and three prong molded rubber plug.
Fan cooled, copper tube with aluminum fins. Fan
motor is permanently lubricated.
Combination tube-tank type. Tube portion is
continuous coil of copper tubing. Fully insulated with EPS
foam which meets Underwriters Laboratories Inc. require-
ments for self extinguishing material.
Ref
rigerant HFC-134a
is controlled
by accurately calibrated capillary
tube for positively trouble-
free operation.
Two Station Wall Mount Water Cooler
Vandal-Resistant, Barrier-Free Access
Model LVRCTL8SC
®
S P E C I F I C AT I O N S
CAPACITIES CHART
**Based on 80°F (27°C) inlet water temperature.
Rated watts shown are based on operational (run) time, in accordance with A.R.I.
Standard 1010 conditions. Specific applications will determine the actual watts
consumed per hour. Watts consumed will be based on number of people
served per hour (usage), ambient temperatures, and inlet water temperature.
Enclosed adjustable thermostat is
factory preset. Requires no adjustment other than for altitude
requirements. Easily accessible.
CONSTRUCTION
alvanized structural steel chassis supports fountain
top and cabinet panels.
Series 300 one piece stainless steel top,
polished to a uniform Elkay bright luster finish. Basin has
embossed bubbler pad.
eavy duty, one piece construc-
tion. Keyed into position to prevent rotation. Meets UL
requirements an
d all sanitary codes.
abinet design allows for flush to wall mounting. No
recess space is required. Include
s bottom cover plate
fastened with vandal-resistant screws.
Stainless steel furnished as standard.
ALSO AVAILABLE
Same as model above, which
includes frost resistant heating element. Tested to 32°F (0°C)
with no wind. Specify for areas where the temperature will
occasionally drop to freezing for a sho
rt period of time. (Glass
Same as LVRCTL8S with perforated
stainless steel louvers screening prevents objects from being
inserted into coolers. LVRCTLSCDDSC also available.
Protected by
Elkay’s 5 Year Limited Warranty on the refrig-
eration system of the unit.
Elkay Pressure-Type Water Coolers are designed to operate
on 20 psi (138 KPa) to 105 psi (724 KPa) supply line pressure.
If inlet pressure is above 105 psi (724 KPa), a pressure
reg
ulator must be installed in the supply line. Any damage
caused by reason of connecting this product to supply line
pressures lower than 20 psi (138 KPa) or higher than 105 psi
(724 KPa) is not covered by the warranty.
STANDA
RDS
Model LVRCTL8SC
**GPH of 50°F
Drinking Water
Ship.
Room Temperature °F
Full Glass Wt.
Model Volt./ Base 70°F 80°F 90°F Rated Load Filler Filter Louver Lbs.
Number Hertz Rate (21°C) (27°C) (32°C) Watts Amps Option Option Screens (Kg.)
LVRCTL8SC
120V/
7.8 9.4 8.6 7.8 575 5 No Yes Yes 94
60Hz
220-
LVRCTL8S2JOC 240V/ 6.5 7.9 7.2 6.5 575 2.5 No Yes Yes 94
50Hz
220-
LVRCTL8S3JOC 240V/ 7.5 9.4 8.6 7.8 575 2.5 No Yes Yes 94
60Hz
LVRCTLDDSC No Yes Yes 56
Elkay
2222 Camden Court
Oak Brook, IL 60523
Printed in U.S.A.
©2014 Elkay
(Rev. 2/14)
elkay.com
In keeping with our policy of continuing product improvement, Elkay reserves the right to change
product specifications without notice. Please visit elkayusa.com for most current version.
This specification describes an Elkay product with design, quality and functional benefits to the
user. When making a comparison of other producers’ offerings, be certain these features are not
overlooked.
Elkay Electric Air Cooled Water Coolers are listed
by Underwriters Laboratories Inc. and comply with
both Canadian and U.S. requirements.
These units comply with A.R.I. Standard 1010.
This cooler is certified by WQA to lead-free compliance including
NSF/ANSI 61 and 372.
Model LVRCTLSC8SC
Model LVRCTLFR8SC
filler not available). Model LVRCTLFRDDSC also available.
Color Selection:
CCabinet:
Vandal-resistant bubbler: H
Temperature Control:
Frame:
Cololer Top:
Motor Compressor:
Condenser:
Cooling Unit:
Refrigeration Control:
12-70A
WATERSENTRY
®
VII FILTER SYSTEM
Elkay Water Coolers are equipped with the WaterSentry VII Filter
Yields a reduction of soluble and insoluble lead content to less
than 0.015mg/l. This translates to lead reduction levels of 93%
to 99%. Class 1 particulate reduction as tested per ANSI/NSF
42. Removes over 97.5% of free available chlorine which provides
Class 1 performance as tested to ANSI/NSF 42. Provides taste
and odor improvement.
System, which is tested and certified to ANSI/NSF Standard 53
Filtered

Summary of content (2 pages)