Specification Sheet
C
L
14-1/2"
(368mm)
14-1/2"
(368mm)
WALL LINE
1-1/4" (32mm)
O.D. TAILPIECE
(TRAP NOT FURNISHED)
3/8" O.D.
TUBE CONNECT
COLD WATER SUPPLY
BY OTHERS
TANK
DRAIN
18"
(457mm)
1-3/8"
(35mm)
1"
(25mm)
4-1/8"
(105mm)
3/4"
(19mm)
5-7/16"
(138mm)
3/4"
(19mm)
22"
(559mm)
17"
(432mm)
2-1/2"
(64mm)
5"
(127mm)
5/16" (8mm)
DIA. SCREW HOLES
IN MOUNTING PLATE
40" (1016mm) - ADULTS
33" (838mm) - CHILDREN
ELECTRICAL
OUTLET
LOCATION
(BY OTHERS)
1-1/2 FOOT (457mm) LONG
POWER CORD
OPTIONAL
ELECTRICAL OUTLET
12-1/4"
(311mm)
4-5/8"
(117mm)
RECOMMENDED LOCATION
3/8" I.P.S. COLD WATER SUPPLY
(STUB OUT FROM WALL 1" [25mm])
WASTE OUTLET – 1-1/4" I.P.S.
(STUB OUT FROM WALL 1" [25mm])
1-1/4" (32mm)
O.D. TAILPIECE
7/8"
(22mm)
IMPORTANT!
INSTALLER PLEASE NOTE:
This water cooler has been designed and built to provide
water to the user which has not been altered by materials
in the cooler waterways.
The grounding of electrical equipment such as telephone,
computers, etc., to water lines is a common procedure.
This grounding may be in the building but may also occur
away from the building. This grounding can cause electrical
feedback into a water cooler creating an electrolysis
which creates a metallic taste or causes an increase in the
metal content of the water. This condition is avoidable by
installing the cooler using the proper materials as shown
below.
NOTICE
This water cooler must be connected to the water supply
using a dielectric coupling. The cooler is furnished with a
non-metallic strainer which meets this requirement.
The drain trap which is provided by the installer should
also be plastic to completely isolate the cooler from the
building plumbing system.
WaterSentry
®
VII Filter System
Elkay
2222 Camden Court
Oak Brook, IL 60523
Printed in U.S.A.
©2003 Elkay
8-8G (Rev. 9/03)
Air Cooled Refrigerated Water Cooler
with WaterSentry
®
VII Filter System
Wall-Compact Models LWCE4 and LWCE8
®
ROUGH-IN DIMENSIONS