Installation
EZ8WSLSMC_1G EZ8WSSSMC_1G LZ8WSLSMC_1G LZ8WSSSMC_1G
Elkay Manufacturing Company (630) 574-8484
1000006137 (Rev. A - 03/21)
Page 6
1.37in
35mm
X2
18.38in
467mm
WATER INLET
21.38in
543mm
ELEC. OUTLET
25.00in
635mm
WASTE OUTLET
30.96in
786mm
4.31in 109mm
15.00in
381mm
0.56in
14mm
X2
17.89in
454mm
53.04in
1347mm
3.50in
89mm
WATER INLET
2.50in
63mm
ELEC. OUTLET
5.50in 140mm
BASIN DRAIN
4.50in 114mm
WASTE OUTLET
5.75in 146mm
X2
7.00in 178mm
X2
A
A
FILTER
5/16" (8mm)
MOUNTING HOLES X4
7/16" (11mm)
MOUNTING HOLES X 12
ACTIVATION
SENSOR
X2
WALL
18.38in
467mm
WATER INLET
25.00in
635mm
WASTE OUTLET
12.31in
313mm
27.37in
695mm
BASIN DRAIN
BASIN HEIGHT
34.12in
867mm
39.98in
1016mm
ACTIVATION SENSOR
8.24in 209mm
BASIN DRAIN
11.89in
302mm
3.44in
87mm
18.91in
480mm
SECTION A-A
FLOOR
WALL
FILTER
FLOOR
LEGEND:
RECOMMENDED WATER SUPPLY LOCATION. SHUT-OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE. UP TO 3" (76mm)
MAXIMUM OUT FROM WALL.
A.
RECOMMENDED WASTE OUTLET LOCATION. TO ACCOMODATE 1-1/4" NOMINAL DRAIN. DRAIN STUB 2" (51mm) OUT FROM WALL.
B.
1-1/4" TRAP. (NOT FURNISHED)
C.
ELECTRICAL SUPPLY (3) WIRE RECESSED BOX DUPLEX OUTLET.
D.
INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) MINIMUM CLEARANCE FROM CABINET LOUVERS TO WALL.
E.
7/16" (11mm) BOLT HOLES FOR FASTENING TO WALL.
F.
NOTE:
NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTER (GFCI). IT IS HIGHLY RECOMMENDED THAT THE CIRCUIT BE DEDICATED AND
THE LOAD PROTECTION BE SIZED FOR 20 AMPS.