EZSDWS*1F EZS8WS*1F, 2F, 3F LZSDWS*1F, 2F, 3F LZS8WS*1F, 2F, 3F INSTALLATION, CARE & USE MANUAL Manual de Instalación, Cuidado y Utilización Manuel d’installation/entretien/utilisation EZ & LZ Series Bottle Filling Stations & Coolers TM TM EZ & LZ Serie Botella Bombas y Enfriadores EZ & LZ Stations de Remplissage de Bouteille Série et Refroidisseurs TM TM TM TM Page 1 1000001731 (Rev.
EZSDWS*1F EZS8WS*1F, 2F 3F LZSDWS*1F, 2F, 3F LZS8WS*1F, 2F, 3F Pictured is unit only without bottle filler. Uses HFC-134A refrigerant Usa refrigerante HFC-134A Utilise du fluide frigorigéne HFC-134A 1 14, 25 21 15 8 6 5 See Fig. 3 3 2 12 See Fig. 13 12 12 13 Stream Height Adjustment See Note 8 23 16 21 7 18 4 19 17 20 Fig. 1 1000001731 (Rev.
D E B F 2" 51mm 9/32" O HOLES (7mm) (12) 7" 178mm 6 3/8" 162mm C L 2" 51mm 3 7/8" 98mm 5 3/4" 146mm 7" 178mm 2" 51mm 6 3/8" 162mm 7" 178mm A E 1000001731 (Rev. E - 10/15) 31 5/16" 796mm RIM HEIGHT 27" 686mm ADA REQUIREMENT 3 9/16" 90mm C 12 1/2" 318mm 8 1/16" 205mm HANGER BRACKET 19" 483mm *ADA REQUIREMENT *REQUISITO DE A.D.A.
EZSDWS*1F EZS8WS*1F, 2F 3F LZSDWS*1F, 2F, 3F LZS8WS*1F, 2F, 3F HANGER BRACKETS & TRAP INSTALLATION 1) Remove hanger bracket fastened to back of cooler by removing one (1) screw. 2) Mount the hanger bracket as shown in Figure 2. NOTE: Hanger Bracket MUST be supported securely. Add fixture support carrier if wall will not provide adequate support. Anchor hanger securely to wall using all six (6) 1/4 in. dia. mounting holes. IMPORTANT: 5-7/8 in.
EZSDWS*1F EZS8WS*1F, 2F, 3F LZSDWS*1F, 2F, 3F LZS8WS*1F, 2F, 3F Service Instructions Lower and Upper Shroud To access the refrigeration system and plumbing connections, remove four screws from bottom of cooler to remove the lower shroud. To remove the upper shroud for access to the pushbars, regulator, solenoid valve or other components located in the top of the unit, remove lower shroud, disconnect drain, remove four screws from tabs along lower edge of upper shroud, unplug two wires and water tube.
EZSDWS*1F EZS8WS*1F, 2F 3F LZSDWS*1F, 2F, 3F LZS8WS*1F, 2F, 3F 7/16” BOLT HOLES FOR FASTENING UNIT TO WALL UNIT CENTER LINE TOP COVER Fig. 4 MOUNTING SCREWS 29 Fig. 5 Fig. 7 Fig. 6 BRACKET, WASHERS, & SCREWS Bottle Filler Installation Instructions 1) Remove two (2) mounting screws with 5/32” Allen wrench holding top cover to Bottle Filler (See Fig. 5). Remove top cover. Note do not discard mounting screws, they will be needed to reinstall top cover. 2) Remove wall mounting plate from Bottle Filler.
EZSDWS*1F EZS8WS*1F, 2F, 3F LZSDWS*1F, 2F, 3F LZS8WS*1F, 2F, 3F BF11 PROGRAM SETTING THE CONTROL BOARD VERIFY CONTROL BOARD SOFTWARE 1) To verify the software program of the control board the unit will need to be shut down and restarted. The chiller (if present) does not need to be shut down and restarted. 2) The units lower panel must be open to access the power cord and wall outlet. 3) Shut down the unit by unplugging the power cord from the wall outlet.
EZSDWS*1F EZS8WS*1F, 2F 3F LZSDWS*1F, 2F, 3F LZS8WS*1F, 2F, 3F OVERLOAD 14 BLK 3 1 2 COLD CONTROL 24 NOISE SUPPRESSOR PURPLE TO BOTTLE FILLER C FAN SOLENOID VALVE 5 3 2 1 WHT RELAY (BLACK - L) 6 GREEN - GND M S 14 (WHITE - N) WALL MOUNTING PLATE GND Fig. 10 115V Refrigerated Wiring Diagram Diagrama de Cableado Refrigerados de 115 Voltios Schéma Frigorifique de 115 Volts SWITCHES 24 NOISE SUPPRESSOR PURPLE TO BOTTLE FILLER Fig.
EZSDWS*1F EZS8WS*1F, 2F, 3F LZSDWS*1F, 2F, 3F LZS8WS*1F, 2F, 3F NOTE: When installing replacement bubbler and pedestal, tighten nut only to hold parts snug in position. Do Not Overtighten. NOTA: Al instalar el grifo y pedestal de reemplazo, apriete la tuerca unicamente para mantener las piezas en una posicion adjustada. No dede apretarse demasiado. 11 REMARQUE: Lors de L’installation du barboteur de remplacement ou du socle, serez la vis afin de maintenir les elemants en place.
EZSDWS*1F EZS8WS*1F, 2F 3F LZSDWS*1F, 2F, 3F LZS8WS*1F, 2F, 3F 115V PARTS LIST/ 115V LISTA DE PIEZAS/ 115V LISTE DES PIÈCES ITEM NO. PART NO.