Installation Instructions

98526C (Rev. C - 1/13)Page 1
WaterSentry
®
Plus Retro Bottle Filler and Water Cooler.
7. Turn on water supply and hold open the bubbler on
cooler until approximately 1 gallon of water is dis-
pensed.This flushing procedure purges air and fine
carbon particles from the filter. When 1 gallon of water
has been purged through the cooler, carefully inspect
all water connections for leaks.
FOR COMMERCIAL USE ONLY
These filter kits are designed to be used with the following
Elkay product.
1. LZS
NOTICE: Do not use with water that is microbiologically
unsafe or of unknown quality without adequate
disinfection before or after the system.
Filter must be used with filter monitor for 3000
gallon rating
General Installation Instructions
1. These filter kits must be installed in compliance with all
state and local laws and regulations governing the
installation and use of this product. Maximum inlet
water temperature 100°F (38°C).
2. Mount filter head in a suitable location, using the filter
mounting bracket and screws supplied. Allow enough
room under the filter head for installation and removal of
filter cartridge (13" minimum).
3. Connect the cold water supply to the filter through a
shut-off valve and 3/8" O.D. tubing (supplied by the
installer). For ease of servicing, the shut-off valve
should be located within easy reach of the filter.
NOTE: The inlet and outlet fitting supplied as
part of the filter head are John Guest Superseal
fittings that accept 3/8" O.D. tubing on the filter
inlet and 1/4" O.D. tubing on the outlet. They may
be used with copper, stainless steel, or semirigid
nylon or polypropylene tubing, with a rated working
pressure equal or greater than encountered in
application. Do not use soft or braided tubing.
4. CAUTION: If supply pressure will ever exceed
100 psi, install a pressure regulator to limit the
inlet pressure to the filter to 100 psi or below.
DO NOT ATTACH HOT WATER LINE TO FILTER.
To make connections on the filter head, loosen locknut.
Push the tube end past both o-rings to a positive stop in
the filter head recess - approx. 1", locknut may have to
be backed out a little more. Screw the locknut hand tight
to seal (See Fig. 1). Ends of tubing must be cut square
and free of burrs and sharp ends that could cut or nick
the o-rings.
5. Connect the outlet of the filter to the inlet of the union
using the 1/4" O.D. poly tubing and 1/4" union supplied.
6. Remove filter from carton, remove protective cap, attach
filter to filter head by firmly inserting into head and
rotating filter clockwise.
FIG. 2
FIG. 1
See Note 4: Screw the locknut hand tight to seal
Filter Replacement*
1.Turn inlet water valve off.
2.Open bubbler or activate the electric eye to relieve pressure
build-up in the system.
3.Remove filter from head by rotating filter counterclock
wise.
4.Remove new filter from carton, remove protective cap;
cap may be placed on old filter to reduce the chance of
water spilling from filter housing.
5.Attach filter to filter head by firmly inserting into head
and rotating filter clockwise.
WaterSentry
®
Plus In Wall Bottle Filler .
7. Turn on water supply and activate the electric eye on
In Wall Bottle Filler until approximately 1 gallon of
water is dispensed. Please note that the electric eye
activation times out at 30 seconds and will need to
be activate repeatedly until one gallon has been
passed. This flushing procedure purges air and fine
carbon particles from the filter. When 1 gallon of water
has been purged through the bottle filler, carefully
inspect all water connections for leaks.
FILTER KIT
EWF3000 Watersentry
®
Plus KIT
(Lead, Aesthetic Chlorine Taste & Odor & Particulate Class I Reduction)
FOR COMMERCIAL USE ONLY
The Elkay
®
WaterSentry
®
Plus is certified by WQA to NSF/ANSI Standard 42 and 53 for the
reduction of
Aesthetic Chlorine, Taste and Odor, Particulate Class I, and Lead, as verified and
substantiated by test data.
®

Summary of content (4 pages)