Spec Sheet

SPECIFICATIONS
Elkay ezH2O Vandal-Resistant Bottle Filling Station
& Bi-Level Cooler
Non-Filtered Refrigerated Stainless
Model VRCTL8WSK
In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkay.com for
the most current version of Elkay product specification sheets. This specification describes an Elkay product with design, quality, and functional benefits to the user.
When making a comparison of other producers’ offerings, be certain these features are not overlooked.
Elkay REV 05082021 1333 Butterfield Road, Suite 200 © 2021 Page 1
VRCTL8WSK Downers Grove, IL 60515 VRCTL8WSK_spec.pdf
PRODUCT SPECIFICATIONS
Elkay ezH2O® Vandal-Resistant Bottle Filling Station, & Bi-Level
Cooler, Non-Filtered Refrigerated Stainless. Chilling Capacity of 8.0
GPH (gallons per hour) of 50 F drinking water, based on 80 F inlet
water and 90 F ambient, per ASHRAE 18 testing. Features shall
include Green Ticker™, Laminar Flow, Real Drain, Vandal Resistant.
Furnished with Vandal Resistant bubbler. Electronic Bottle Filler Button
with Mechanical Front Bubbler Button activation. Product shall be Wall
Mount (On Wall), for Indoor + Outdoor applications, serving 2 station(s).
Unit shall be certified to UL 399 and CAN/CSA C22.2 No. 120. Unit
shall be lead-free design which is certified to NSF/ANSI 61 & 372 (lead
free) and meets Federal and State low-lead requirements.
Special Features:
Green Ticker™, Laminar Flow, Real
Drain, Vandal Resistant
Finish:
Stainless Steel
Power:
115V/60Hz
Bubbler Style:
Vandal Resistant
Activation by:
Electronic Bottle Filler Button with
Mechanical Front Bubbler Button
Mounting Type:
Wall Mount (On Wall)
Chilling Capacity*:
8.0 GPH
Full Load Amps
1
Rated Watts:
370
Dimensions (L x W x H):
36-1/8" x 18-5/8" x 38-13/16"
Approx. Shipping Weight:
118 lbs.
Installation Location:
Indoor + Outdoor
No. of Stations Served:
2
*Based on 80° F inlet water & 90° F ambient air temp for 50° F chilled
drinking water.
Mechanically-Activated bubbler continues to supply water in
event of service disruptions.
Green Ticker: Informs user of number of 20 oz. plastic water
bottles saved from waste.
Laminar flow provides clean fill with minimal splash.
Real Drain System eliminates standing water.
COOLING SYSTEM
Compressor: Hermetically-sealed, reciprocating type,
single phase. Sealed-in lifetime lubrication.
Condenser: Fan cooled, copper tube with aluminum
fins. Fan motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Continuous
copper tubing with is fully insulated with EPS foam that
meets UL requirements for self-extinguishing material.
Refrigerant Control: Refrigerant R-134a is controlled by
accurately calibrated capillary tube.
Temperature Control: Easily accessible enclosed
adjustable thermostat is factory preset. Requires no
Included with Product:
Water Cooler (VRCTL8WSC),
Bottle Filler (VRCWS)
Ships in multiple boxes.
PRODUCT COMPLIANCE
ADA & ICC A117.1
ASME A112.19.3/CSA B45.4
Buy American Act
CAN/CSA C22.2 No. 120
GreenSpec
®
NSF/ANSI 61 & 372 (lead free)
UL 399
Complies with ADA & ICC A117.1 accessibility requirements when installed
according to the requirements outlined in these standards. Installation may
require additional components and/or construction features to be fully
compliant. Consult the local Authority Having Jurisdiction if necessary.
Installation Instructions (PDF)
5 Year Limited Warranty on the refrigeration system of the unit.
Electrical components and water system are warranted for 12 months
from date of installation. Warranty pertains to drinking water
applications only. Non-drinking water applications are not
covered under warranty.
Warranty (PDF)
OPTIONAL ACCESSORIES
EWF3000 - Elkay WaterSentry Plus Filter System Kit (Bottle Fillers)
98324C - Accessory - Cane Apron for HAC, HVR, EMABF & VRC
Models (Stainless)
36292C - Accessory - Power Block for Multistation Bottle Filling
Stations
PART:________________________________QTY: _____________
PROJECT:______________________________________________
CONTACT:______________________________________________
DATE:__________________________________________________
NOTES:_________________________________________________
APPROVAL:_____________________________________________

Summary of content (2 pages)