Specification Sheet

GENERAL
Self-contained, double wall hung electric refrigerated, water
cooler. Vandal-resistant unit for use in high demand locations
where vandalism may occur. Rated for indoor or outdoor use.
Stainless steel construction provides vandal-resistant
enclosure. Optional perforated stainless steel louver screen-
ing prevents objects from being inserted into cooler. Flow
regulator provides constant stream fr
om 20 to 105 psi water
pr
essure. Heavy duty push button control is vandal-resistant.
ADA COMPLIANT
These Water Coolers comply with the requirements of A.D.A.
(Americans with Disabilities Act) when properly installed. Also
meets the guidelines for children’s environments providing
the floor to orifice height is 30" or less and proper clear floor
space is provided for parallel approach. (Based on
Architectu
ral and Transportation Barriers Compliance Board
fina
l ruling.) Check Local and State Codes.
NO LEAD DESIGN
These Water Coolers are certified to be lead-free as defined
by the Safe Drinking Water Act. Elkay Water Coolers are man-
ufactured with a waterway system utilizing copper compo-
nents and completely lead-free materials. These waterways
have no lead because all lead materials, such as leaded
brass, have been removed. All joints are brazed using silver
sold
er only. No lead solder is permitted. A strainer with an
easily cleanable screen is provided to allow trapping and con-
venient removal of waterborne particulate of 140 microns and
larger prior to their entry into the water cooler.
COOLING SYSTEM
Hermetically sealed, reciprocating type,
120 Volt/60 Hz, single phase or 220-240 Volt/50 Hz or 60 Hz,
two phase. Sealed-in lifetime oil supply. Equipped with elec-
tric
cord and three prong molded rubber plug.
Fan cooled, copper tube with aluminum fins. Fan
motor is permanently lubricated.
Combination tube-tank type. Tube portion is
continuous coil of copper tubing. Fully insulated with EPS
foam which meets Underwriters Laboratories Inc. require-
ments for self extinguishing material.
Refrigerant HFC-134a
is controlled
by accurately calibrated capillary tube for positively trouble-
free operation.
Two Station Wall Mount Water Cooler
Vandal-Resistant, Barrier-Free Access
Model VRCTL8SC
®
SPECIFICATIONS
CAPACITIES CHART
**Based on 80°F (27°C) inlet water temperature.
Rated watts shown are based on operational (run) time, in accordance with A.R.I.
Standard 1010 conditions. Specific applications will determine the actual watts
consumed per hour. Watts consumed will be based on number of people
served per hour (usage), ambient temperatures, and inlet water temperature.
Enclosed adjustable thermostat is
factory preset. Requires no adjustment other than for altitude
requirements. Easily accessible.
CONSTRUCTION
alvanized structural steel chassis supports fountain
top and cabinet panels.
Series 300 one piece stainless steel top,
polished to a uniform Elkay bright luster finish. Basin has
embossed bubbler pad.
eavy duty, one piece construc-
tion. Keyed into position to prevent rotation. Meets UL
requirements an
d all sanitary codes.
ab
inet design allows for flush to wall mounting. No
recess space is required. Includes bottom cover plate
fastened with vandal-resistant screws.
Stainless steel furnished as standard.
ALSO AVAILABLE
Same as model above, which
includes frost resistant heating element. Tested to 32°F (0°C)
with no wind. Specify for areas where the temperature will
occasionally drop to freezing for a sho
rt period of time. (Glass
Sa
me as VRCTL8S with perforated
stainless steel louvers screening prevents objects from being
inserted into coolers. VRCTLSCDDSC also available.
Protected by Elkay’s 5 Year Limited Warranty on the refrig-
eration system of the unit.
Elkay Pressure-Type Water Coolers are designed to operate
on 20 psi (138 KPa) to 105 psi (724 KPa) supply line pressure.
If inlet pressure is above 105 psi (724 KPa), a pressure
reg
ulator must be installed in the supply line. Any damage
ca
used by reason of connecting this product to supply line
pressures lower than 20 psi (138 KPa) or higher than 105 psi
(724 KPa) is not covered by the warranty.
STANDARDS
Model VRCTL8SC
**GPH of 50°F
Drinking Water
Ship.
Room Temperature °F
Full Glass Wt.
Model Volt./ Base 70°F 80°F 90°F Rated Load Filler Filter Louver Lbs.
Number Hertz Rate (21°C) (27°C) (32°C) Watts Amps Option Option Screens (Kg.)
VRCTL8SC
120V/
7.8 9.4 8.6 7.8 575 5 No Yes Yes 94
60Hz
220-
VRCTL8S2JOC 240V/ 6.5 7.9 7.2 6.5 575 2.5 No Yes Yes 94
50Hz
220-
VRCTL8S3JOC 240V/ 7.5 9.4 8.6 7.8 575 2.5 No Yes Yes 94
60Hz
VRCTLDDSC ––– No Yes Yes 56
Elkay
2222 Camden Court
Oak Brook, IL 60523
Printed in U.S.A.
©2013 Elkay
(Rev. 1/13)
elkayusa.com
In keeping with our policy of continuing product improvement, Elkay reserves the right to change
product specifications without notice. Please visit elkayusa.com for most current version.
This specification describes an Elkay product with design, quality and functional benefits to the
user. When making a comparison of other producers’ offerings, be certain these features are not
ov
erlooked.
Elkay Electric Air Cooled Water Coolers are listed
by Underwriters Laboratories Inc. and comply with
both Canadian and U.S. requirements.
These units comply with A.R.I. Standard 1010.
This cooler is certified by WQA to lead-free compliance including
NSF/ANSI 61 and 372.
Model VRCTLSC8SC
Model VRCTLFR8SC
filler not available). Model VRCTLFRDDSC also available.
Color Selection:
CCabinet:
Vandal-resistant bubbler: H
Temperature Control:
Frame:
Cololer Top:
Motor Compressor:
Condenser:
Cooling Unit:
Refrigeration Control:

Summary of content (2 pages)