Specification Sheet

GENERAL
Self-contained, double wall hung electric refrigerated, water
cooler. Vandal-resistant unit for use in high demand locations
where vandalism may occur. Rated for indoor or outdoor use.
Stainless steel construction provides vandal-resistant
enclosure. Optional perforated stainless steel louver screen-
ing prevents objects from being inserted into cooler.
Patented* valve with built-in flow regulator provide constant
stream from 20 to 105 psi (138 to 724 KPa) water pressure.
Heavy duty push button control is vandal-resistant.
ADA COMPLIANT
These Water Coolers comply with the requirements of A.D.A.
(Americans with Disabilities Act) when properly installed. Also
meets the guidelines for children’s environments providing
the floor to orifice height is 30" or less and proper clear floor
space is provided for parallel approach. (Based on
Architectural and Transportation Barriers Compliance Board
final ruling.) Check Local and State Codes.
NO LEAD DESIGN
These Water Coolers are certified to be lead-free as defined
by the Safe Drinking Water Act. Elkay Water Coolers are man-
ufactured with a waterway system utilizing copper compo-
nents and completely lead-free materials. These waterways
have no lead because all lead materials, such as leaded
brass, have been removed. All joints are brazed using silver
solder only. No lead solder is permitted. A strainer with an
easily cleanable screen is provided to allow trapping and con-
venient removal of waterborne particulate of 140 microns and
larger prior to their entry into the water cooler.
These water coolers are certified to NSF/ANSI 61.
COOLING SYSTEM
Motor Compressor: Hermetically sealed, reciprocating type,
120 Volt/60 Hz, single phase or 220-240 Volt/50 Hz or 60 Hz,
two phase. Sealed-in lifetime oil supply. Equipped with elec-
tric cord and three prong molded rubber plug.
Condenser: Fan cooled, copper tube with aluminum fins. Fan
motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Tube portion is
continuous coil of copper tubing. Fully insulated with EPS
foam which meets Underwriters Laboratories Inc. require-
ments for self extinguishing material.
Two Station Wall Mount Water Cooler
Vandal-Resistant, Barrier-Free Access
Model VRCTLR8SC
®
SPECIFICATIONS
CAPACITIES CHART
**Based on 80°F (27°C) inlet water temperature.
Rated watts shown are based on operational (run) time, in accordance with A.R.I.
Standard 1010 conditions. Specific applications will determine the actual watts
consumed per hour. Watts consumed will be based on number of people
served per hour (usage), ambient temperatures, and inlet water temperature.
Refrigerant Control: Refrigerant HFC-134a is controlled by
accurately calibrated capillary tube for positively trouble-free
operation.
Temperature Control: Enclosed adjustable thermostat is
factory preset. Requires no adjustment other than for altitude
requirements. Easily accessible.
CONSTRUCTION
Frame: Galvanized structural steel chassis supports fountain
top and cabinet panels.
Fountain Top: Series 300 one piece stainless steel top,
polished to a uniform Elkay bright luster finish. Basin has
embossed bubbler pad.
Vandal-Resistant Bubbler: Heavy duty, one piece construc-
tion. Keyed into position to prevent rotation. Meets UL
requirements and all sanitary codes.
Cabinet: Cabinet design allows for flush to wall mounting. No
recess space is required. Includes bottom cover plate
fastened with vandal-resistant screws.
Color Selection: Stainless steel furnished as standard.
ALSO AVAILABLE
MODEL VRCSCTLR8SC:
Same as VRCTLR8SC model with
perforated stainless steel louvers screening prevents objects
from being inserted into coolers.
5 YEAR LIMITED WARRANTY
on the refrigeration system of
the unit. Electrical components and water system are war-
ranted for 12 months from date of installation. Sample
Certificate available on request.
Elkay Pressure-Type Water Coolers are designed to operate
on 20 psi (138 KPa) to 105 psi (724 KPa) supply line pressure.
If inlet pressure is above 105 psi (724 KPa), a pressure
regulator must be installed in the supply line. Any damage
caused by reason of connecting this product to supply line
pressures lower than 20 psi (138 KPa) or higher than 105 psi
(724 KPa) is not covered by the warranty.
STANDARDS
Model VRCTLR8SC
Elkay
2222 Camden Court
Oak Brook, IL 60523
Printed in U.S.A.
©2009 Elkay
elkayusa.com
In keeping with our policy of continuing product improvement, Elkay reserves the right to change
product specifications without notice.
This specification describes an Elkay product with design, quality and functional benefits to the
user. When making a comparison of other producers’ offerings, be certain these features are not
overlooked.
* Patent #4,481,971
**GPH of 50°F
Drinking Water
Ship.
Room Temperature °F
Full Glass Wt.
Model Volt./ Base 70°F 80°F 90°F Rated Load Filler Filter Louver Lbs.
Number Hertz Rate (21°C) (27°C) (32°C) Watts Amps Option Option Screens (Kg.)
VRCTLR8SC
120V/
7.8 9.4 8.6 7.8 575 5 No Yes Yes 94
60Hz
220-
VRCTLR8S2JOC
240V/ 6.5 7.9 7.2 6.5 575 2.5 No Yes Yes 94
VRCTLR8S3JOC
240V/ 7.5 9.4 8.6 7.8 575 2.5 No Yes Yes 94
60Hz
VRCTLRDDSC ––––
Elkay Electric Air Cooled Water Coolers are listed
by Underwriters Laboratories Inc. and comply with
both Canadian and U.S. Requirements.
No Yes Yes 56